Founded in 2012, Shree Vijayvargiya Technologies Pvt. Ltd. is a leading provider of industrial and commercial supplies, specializing in industrial switchgear and automation products. We focus on excellence, innovation, and customer delight across wholesale, distribution, and automation solutions.

Our Socials

Omron E5DC Temperature Controller

Omron E5DC Series Temperature Controller

The Omron E5DC is a DIN-rail mountable digital temperature controller designed for compact control panels and distributed temperature control systems. Despite its small footprint, it delivers high-speed and high-accuracy temperature control with advanced features like 2-PID control, fast 50 ms sampling, and removable terminal block wiring for easy maintenance.

Categories:

Panel Components

Key Features

  • Ultra-Compact Size (22.5 mm width) – Ideal for space-limited control panels and multi-loop control
  • DIN Rail Mounting – Fast installation and space-saving design
  • Removable Terminal Block – Simplifies wiring, reduces downtime during replacement
  • 50 ms High-Speed Sampling – Quick response time for precise control
  • Advanced 2-PID Control Algorithm – Stable control for fast-heating systems and complex loads
  • Easy Configuration
    • USB setup using CX-Thermo software
    • Supports RS-485 Modbus communication
  • Universal Input – Supports thermocouples, RTDs, voltage, and current signals
  • Multiple Outputs – Relay, voltage pulse (SSR), current (4–20 mA)
  • Event Inputs & Alarms – Versatile function assignment for digital input
Specifications Details
Power supply voltage A in model number: 100 to 240 VAC, 50/60 Hz D in model number: 24 VAC, 50/60 Hz; 24 VDC
Operating voltage range 85 to 110% of rated supply voltage
Power consumption 4.9 VA max. at 100 to 240 VAC, and 2.8 VA max. at 24 VDC or 1.5 W max. at 24 VDC
Sensor input Temperature input Thermocouple: K, J, T, E, L, U, N, R, S, B, C/W, or PL II Platinum resistance thermometer: Pt100 or JPt100 Infrared temperature sensor (ES1B): 10 to 70°C, 60 to 120°C, 115 to 165°C, or 140 to 260°C Analog input Current input: 4 to 20 mA or 0 to 20 mA Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V
Input impedance Current input: 150 Ω max., Voltage input: 1 MΩ min. (Use a 1:1 connection when connecting the ES2-HB-N/THB-N.)
Control method ON/OFF control or 2-PID control (with auto-tuning)
Control output Relay output SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum applicable load: 5 V, 10 mA (reference value)
Voltage output (for driving SSR) Output voltage 12 VDC ±20% (PNP), max. Load current: 21 mA, with short-circuit protection circuit
Linear current output 4 to 20 mA DC/0 to 20 mA DC, load: 500 Ω max., resolution: Approx. 10,000
Auxiliary output Number of outputs 2 (depends on model)
Output specifications SPST-NO relay outputs: 250 VAC, 2 A (resistive load), Electrical life: 100,000 operations, Minimum applicable load: 10 mA at 5 V (reference value)
Event input *1 Number of inputs 1 (depends on model)
External contact input specifications Contact input ON: 1 kΩ max., OFF: 100 kΩ min.
Non-contact input ON: Residual voltage 1.5 V max.; OFF: Leakage current 0.1 mA max.
Current flow: approx. 7 mA per contact
Setting method Digital setting using front panel keys
Indication method 11-segment digital displays and individual indicators Character height: PV: 8.5 mm, SV: 8.0 mm
Multi SP Up to eight set points (SP0 to SP7) can be saved and selected using the event inputs, key operations, or serial communications. *2
Bank switching None
Other functions Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions, heater burnout (HB) alarm (including SSR failure (HS) alarm), 40% AT, 100% AT, MV limiter, input digital filter, self tuning, robust tuning, PV input shift, run/ stop, protection functions, extraction of square root, MV change rate limit, logic operations, temperature status display, simple programming, moving average of input value, display brightness setting, simple transfer output, *3 and work bit message *3
Ambient operating temperature -10 to 55°C (with no condensation or icing), For 3-year warranty: -10 to 50°C with standard mounting (with no condensation or icing)
Ambient operating humidity 25 to 85%
Storage temperature -25 to 65°C (with no condensation or icing)
Altitude 2,000 m max.
Recommended fuse T2A, 250 VAC, time-lag, low-breaking capacity
Installation environment Overvoltage category II, Pollution Degree 2 (EN/IEC/UL 61010-1)
Specifications Details
Indication accuracy (when mounted individually, ambient temperature of 23°C) Thermocouple: (±0.3 % of indication value or ±1°C, whichever is greater) ±1 digit max. *1
Platinum resistance thermometer: (±0.2 % of indication value or ±0.8°C, whichever is greater) ±1 digit max.
Analog input: ±0.2% FS ±1 digit max.
CT input: ±5% FS ±1 digit max.
Simple transfer output accuracy ±0.3% FS max.*2
Influence of temperature *3 Thermocouple input (R, S, B, C/W, PL II): (±1% of indication value or ±10°C, whichever is greater) ±1 digit max.
Other thermocouple input: (±1% of indication value or ±4°C, whichever is greater) ±1 digit max. *4
Platinum resistance thermometer: (±1% of indication value or ±2°C, whichever is greater) ±1 digit max.
Analog input: ±1% FS ±1 digit max.
CT input: ±5% FS ±1 digit max.
Influence of voltage *3
Influence of EMS. (at EN 61326-1)
Installation influence (E5DC only) R, S, B, W, or PLII thermocouple: (±1% of PV or ±10°C, whichever is greater) ±1 digit max.
Other thermocouple: (±1% of PV or ±4°C, whichever is greater) ±1 digit max. *4
Input sampling period 50 ms
Hysteresis Temperature input: 0.1 to 999.9°C or °F (in units of 0.1°C or °F)
Analog input: 0.01% to 99.99% FS (in units of 0.01% FS)
Proportional band (P) Temperature input: 0.1 to 999.9°C or °F (in units of 0.1°C or °F)
Analog input: 0.1% to 999.9% FS (in units of 0.1% FS)
Integral time (I) 0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *5
Derivative time (D) 0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *5
Proportional band (P) for cooling Temperature input: 0.1 to 999.9°C or °F (in units of 0.1°C or °F)
Analog input: 0.1% to 999.9% FS (in units of 0.1% FS)
Integral time (I) for cooling 0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *5
Derivative time (D) for cooling 0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *5
Control period 0.1, 0.2, 0.5, 1 to 99 s (in units of 1 s)
Manual reset value 0.0% to 100.0% (in units of 0.1%)
Alarm setting range -1,999 to 9,999 (decimal point position depends on input type)
Influence of signal source resistance Thermocouple: 0.1°C/Ω max. (100 Ω max.)
Platinum resistance thermometer: 0.1°C/Ω max. (10 Ω max.)
Insulation resistance 20 MΩ min. (at 500 VDC)
Dielectric strength 3,000 VAC, 50/60 Hz for 1 min between terminals of different charge
Vibration Malfunction 10 to 55 Hz, 20 m/s² for 10 min each in X, Y and Z directions
Resistance 10 to 55 Hz, 20 m/s² for 2 hr each in X, Y, and Z directions
Shock Malfunction 100 m/s², 3 times each in X, Y, and Z directions
Resistance 300 m/s², 3 times each in X, Y, and Z directions
Weight Main unit: Approx. 80 g, Models with Screw Terminal Unit: Approx. 40 g,
Models with Push-In Plus Terminal Unit: Approx. 40 g
Degree of protection Main unit: IP20, Terminal unit: IP00
Memory protection Non-volatile memory (number of writes: 1,000,000 times)
Setup Tool CX-Thermo version 4.6 or higher
Setup Tool port E5DC/E5DC-B bottom panel: An E58-CIFQ2 USB-Serial Conversion Cable is used to connect a USB port on the computer. *6
E5DC/E5DC-B front panel: An E58-CIFQ2 USB-Serial Conversion Cable and E58-CIFQ2-E Conversion Cable are used together to connect a USB port on the computer. *6
Standards Approved standards cULus: UL 61010-1/CSA C22.2 No.61010-1, Korean wireless regulations (Radio law: KC Mark)
(Some models only.) *7, Lloyd's standards (E5DC only) *8
Conformed standards EN 61010-1 (IEC 61010-1), RCM
EMC EMI: EN61326-1 *9
Radiated Interference Electromagnetic Field Strength: EN55011 Group 1, class A
Noise Terminal Voltage: EN55011 Group 1, class A
EMS: EN61326-1 *9
ESD Immunity: EN61000-4-2
Electromagnetic Field Immunity: EN61000-4-3
Burst Noise Immunity: EN61000-4-4
Conducted Disturbance Immunity: EN61000-4-6
Surge Immunity: EN61000-4-5
Voltage Dip/Interrupting Immunity: EN61000-4-11
Control
output
No. of
auxiliary
outputs
Options Model
HB alarm
and
HS alarm
No. of
event
inputs
Communications Power supply voltage
100 to 240 VAC
Power supply voltage
24 VAC/DC
Relay output --- --- --- RS-485 E5DC-RX0ASM-015 E5DC-RX0DSM-015
E5DC-RX0AUM-015 E5DC-RX0DUM-015
2 --- E5DC-RX2ASM-000 E5DC-RX2DSM-000
E5DC-RX2AUM-000 E5DC-RX2DUM-000
Detection for
single-phase
heater
RS-485 E5DC-RX2ASM-002 E5DC-RX2DSM-002
E5DC-RX2AUM-002 E5DC-RX2DUM-002
1 --- E5DC-RX2ASM-017 E5DC-RX2DSM-017
E5DC-RX2AUM-017 E5DC-RX2DUM-017
Voltage output
(for driving SSR)
--- --- --- RS-485 E5DC-QX0ASM-015 E5DC-QX0DSM-015
E5DC-QX0AUM-015 E5DC-QX0DUM-015
2 --- E5DC-QX2ASM-000 E5DC-QX2DSM-000
E5DC-QX2AUM-000 E5DC-QX2DUM-000
Detection for
single-phase
heater
RS-485 E5DC-QX2ASM-002 E5DC-QX2DSM-002
E5DC-QX2AUM-002 E5DC-QX2DUM-002
1 --- E5DC-QX2ASM-017 E5DC-QX2DSM-017
E5DC-QX2AUM-017 E5DC-QX2DUM-017
Linear current
output
--- --- --- RS-485 E5DC-CX0ASM-015 E5DC-CX0DSM-015
E5DC-CX0AUM-015 E5DC-CX0DUM-015
2 --- E5DC-CX2ASM-000 E5DC-CX2DSM-000
E5DC-CX2AUM-000 E5DC-CX2DUM-000
RS-485 E5DC-CX2ASM-015 E5DC-CX2DSM-015
E5DC-CX2AUM-015 E5DC-CX2DUM-015
1 --- E5DC-CX2ASM-016 E5DC-CX2DSM-016
E5DC-CX2AUM-016 E5DC-CX2DUM-016
Catalog Name
Catalog Number[size]
Last Update
E5C, E5C-T Data Sheet H177-E1-16
[40802KB]
Dec 01, 2023
E5C Brochure H220-E1-04
[4605KB]
Oct 02, 2023
NX-HTC/NX-TC/EJ1/E5DC-B/E5 D-H Catalog H237-E1-05
[3286KB]
May 26, 2025
Value Design for Panel Catalog Y235-E1-07
[5229KB]
May 19, 2025

Applications

  • Plastic forming & molding equipment
  • Semiconductor machinery
  • Compact heat sealing or packing machines
  • Distributed control in modular machinery
  • Environmental test chambers

Why Choose

  • Perfect for narrow enclosures or multi-zone temperature systems
  • Reduces panel space by up to 70% compared to panel-mount controllers
  • Plug-in design for easy module replacement
  • Energy efficient – low power consumption
  • Great value for OEMs and machine builders