Founded in 2012, Shree Vijayvargiya Technologies Pvt. Ltd. is a leading provider of industrial and commercial supplies, specializing in industrial switchgear and automation products. We focus on excellence, innovation, and customer delight across wholesale, distribution, and automation solutions.

Our Socials

ProstarM Dealer & Distributor

Our Products

Types of Prostarm UPS Models Available

Complete Guide to ProstarM UPS Systems for Industrial Power Backup

ProstarM is a UPS brand Shree Vijayvargiya Technologies (SVT) supplies to plant maintenance teams, panel builders and purchase managers across Gujarat and India. The range covers three-phase online double-conversion UPS systems used to protect critical equipment from power outages and voltage disturbances.

ProstarM UPS systems are offered in several series covering different capacity needs, from general industrial backup to high capacity, critical power applications. This guide explains the range and the factors to check before choosing a UPS for a given load.

Choosing a UPS is not just about matching a kVA number to a load. Startup surges, future expansion plans and the battery backup time required during an outage all affect which series and configuration makes sense for a given site. The sections below cover typical applications and the practical checks worth running before placing an order.

ProstarM UPS Series We Supply

PM660 Series

Suited to general industrial backup needs where a compact online UPS is required.

PM800 Series

A mid-capacity option for industrial and commercial loads that need stable, continuous power.

PM890 and PM890-IR Series

Three-phase online double-conversion UPS systems with DSP control and IGBT inverter technology, built for demanding industrial environments and supporting parallel operation for added capacity.

PM990-G4 Series

Designed for high capacity and critical power applications where maximum reliability is required.

ProstarM UPS System Range

Covers the full line of ProstarM UPS models together, useful for comparing series side by side before deciding on a capacity tier.

Where ProstarM UPS Systems Are Used

  • Manufacturing plants - UPS backup protects PLCs, drives and control panels during power interruptions
  • Data centers and server rooms - continuous clean power protects sensitive IT equipment
  • Process industries - UPS systems prevent process upsets caused by voltage dips or outages
  • Automation systems - control panels stay powered through short outages, avoiding unplanned stoppages
  • Infrastructure projects - UPS systems support critical loads during construction and commissioning
  • Generator-backed installations - UPS bridges the gap between a power cut and generator start-up
  • Pharmaceutical and food processing plants - stable power keeps process equipment and monitoring systems running
  • Commercial buildings - UPS protects lifts, security systems and critical facility equipment during outages

Why Buy ProstarM UPS Systems from Shree Vijayvargiya Technologies

  • SVT supplies genuine ProstarM UPS systems across the PM660, PM800, PM890, PM890-IR and PM990-G4 series.
  • The team helps customers size a UPS to the connected load and plan for backup time and future capacity.
  • SVT is based in Ahmedabad, Gujarat, and supports customers across Gujarat and India.
  • A single supplier for UPS systems simplifies planning for critical power backup across a plant.
  • SVT's technical team is available before and after the order to help confirm capacity, battery runtime and parallel options.

How to Choose the Right ProstarM UPS

  1. Size the UPS to the connected load Total load in kVA, including startup surges, should stay within the chosen UPS series' capacity with reasonable headroom.
  2. Check if parallel operation is needed If future load growth is expected, choosing a series that supports parallel (N+X) operation allows capacity to be added later.
  3. Confirm backup time required Battery runtime needed during an outage affects battery bank sizing alongside the UPS unit itself.
  4. Consider power factor and efficiency A higher output power factor means more usable power is available from the same UPS rating.
  5. Plan for integration with generators Compatibility with generator backup should be confirmed if the installation already has or plans to add a generator.
  6. Review available floor space and ventilation Larger capacity UPS series need adequate space and cooling, so the installation room should be checked before finalising a model.
  7. Factor in future load growth If more equipment is likely to be added later, a series that supports parallel expansion avoids replacing the entire system.

Frequently Asked Questions

Which ProstarM UPS series should I choose?
It depends on the load size and criticality. Smaller general purpose loads suit the PM660 or PM800 series, while demanding or critical applications are better served by the PM890, PM890-IR or PM990-G4 series.
Can ProstarM UPS systems be used in parallel?
Yes, series such as PM890 support parallel operation, which allows additional capacity to be added without replacing the existing unit.
How is UPS backup time determined?
Backup time depends on the connected load and the battery bank capacity paired with the UPS. SVT's team can help work out the right battery sizing for the required runtime.
Is ProstarM UPS suitable for industrial automation panels?
Yes, ProstarM UPS systems are commonly used to keep PLCs, drives and control panels powered through short outages, preventing unplanned stoppages.
What maintenance does a ProstarM UPS need?
Routine checks typically cover battery condition, cooling fans and connection tightness. SVT can advise on a maintenance schedule appropriate for the specific series and how heavily it is used.
Rajkot Machine Tools Show 2026
Upcoming Event · In 18 days

Rajkot Machine Tools Show 2026

25–28 Nov 2026 · Hall No. 4, Stall P-5

View Event & Book Slot