Founded in 2012, Shree Vijayvargiya Technologies Pvt. Ltd. is a leading provider of industrial and commercial supplies, specializing in industrial switchgear and automation products. We focus on excellence, innovation, and customer delight across wholesale, distribution, and automation solutions.

Our Socials

ABB Dealer & Distributor

Our Products

Range of ABB Switchgear Products

Complete Guide to ABB Switchgear for Industrial Power Control

ABB is one of the switchgear brands Shree Vijayvargiya Technologies (SVT) supplies to panel builders, OEM machine builders and plant maintenance teams across Gujarat and India. The range covers the core components used to control, protect and isolate electrical circuits inside industrial and commercial power systems.

Selecting the right ABB switchgear type matters because each product family does a different job, from switching a motor on and off to protecting a full distribution board from overload or short circuit current. This guide covers the ABB switchgear types SVT supplies and how to choose between them.

ABB Switchgear Types We Supply

ABB Power Contactor Switchgear

Used for switching motors and electrical circuits on and off, these contactors handle frequent operation cycles reliably.

ABB MCB Switchgear

Miniature circuit breakers that protect wiring and smaller circuits from overload and short circuit conditions.

ABB MCCB Switchgear

Moulded case circuit breakers rated for higher currents, used to protect larger feeders and distribution boards.

ABB MPCB Switchgear

Motor protection circuit breakers sized specifically to protect individual motors from overload and short circuit faults.

ABB ACB Switchgear

Air circuit breakers used at the main incoming supply or large distribution points where high current protection is needed.

ABB Changeover Switch

Switches that transfer a load between two power sources, such as mains and a generator, without manual rewiring.

Where ABB Switchgear Is Used

  • Industrial control panels - contactors and breakers switch and protect motor circuits
  • Main distribution boards - MCCBs and ACBs protect incoming supply and large feeders
  • Machine control cabinets - MPCBs protect individual motors on production machinery
  • Commercial and office buildings - MCBs protect lighting and small power circuits
  • Standby power setups - changeover switches transfer load between mains and generator supply
  • EPC and infrastructure projects - a full range of switchgear covers protection needs from a single panel

Why Buy ABB Switchgear from Shree Vijayvargiya Technologies

  • SVT supplies genuine ABB switchgear across the full range, from contactors to breakers to changeover switches, from a single source.
  • The team helps panel builders and maintenance teams pick the right switchgear type and rating for the application.
  • SVT is based in Ahmedabad, Gujarat, and serves customers across Gujarat and India.
  • Working with one switchgear supplier for contactors, breakers and changeover switches simplifies panel design and ordering.

How to Choose the Right ABB Switchgear

  1. Identify what you are protecting A motor circuit usually needs a contactor plus an MPCB, while a distribution board needs an MCCB or ACB sized to the feeder.
  2. Check the current rating needed Match the breaker or contactor rating to the actual load current and allow for starting current on motor circuits.
  3. Consider switching frequency Circuits that switch on and off often, such as motors, need a contactor rated for frequent operation, not just a breaker.
  4. Check fault current level at the installation Breakers must be rated to safely interrupt the maximum fault current expected at that point in the system.
  5. Plan for backup power if needed If the installation needs to switch between mains and generator power, a changeover switch should be included in the panel design.

Frequently Asked Questions

What is the difference between an MCB and an MCCB?
An MCB is rated for lower currents and is typically used for smaller circuits such as lighting and small power. An MCCB is built for higher current ratings and is used to protect larger feeders and distribution boards.
Do I need an MPCB if I already have a contactor?
Yes, a contactor switches the motor on and off but does not provide overload protection on its own. An MPCB or overload relay is needed alongside the contactor to protect the motor from sustained overload.
Can ABB changeover switches be used with a generator?
Yes, ABB changeover switches are commonly used to transfer a load between the mains supply and a generator, and should be sized to the full load current of the circuit being switched.
How do I know what ampere rating to order?
The rating should be based on the actual load current of the circuit, with some margin for starting current where motors are involved. SVT's team can help confirm the right rating for your panel.
Rajkot Machine Tools Show 2026
Upcoming Event · In 18 days

Rajkot Machine Tools Show 2026

25–28 Nov 2026 · Hall No. 4, Stall P-5

View Event & Book Slot