Founded in 2012, Shree Vijayvargiya Technologies Pvt. Ltd. is a leading provider of industrial and commercial supplies, specializing in industrial switchgear and automation products. We focus on excellence, innovation, and customer delight across wholesale, distribution, and automation solutions.

Our Socials

Omron E5AC Temperature Controller

Omron E5AC Series Temperature Controller

The E5AC is a high-performance temperature controller from Omron’s popular E5_C series, designed for applications that demand accuracy, fast response, and a large display. With its 96 x 96 mm (1/4 DIN) housing, the E5AC is perfect for panel-mounted applications requiring clear visibility and robust performance.

Categories:

Panel Components

Key Features

  • Large White LCD Display (White PV, Green SV)
    • Outstanding visibility from any angle, even in dark environments
    • 3-color status display improves operational awareness
  • Fast 50 ms Sampling Period – High-speed, high-accuracy feedback for fast processes
  • 2-PID Control Algorithm with Auto-Tuning – Stable and responsive temperature control
  • Wide Range of Inputs – Supports thermocouples, RTDs, voltage, and current
  • Multiple Output Options – Relay, voltage pulse for SSR, current (4–20 mA)
  • Built-in RS-485 Communication (Modbus) – Easy integration into automation networks
  • USB Port for Easy Parameter Setup – Configure via CX-Thermo software without power-on
  • Global Standards Compliance – CE, UL, CSA, and RoHS certified
Specifications Details
Power supply voltage A in model number: 100 to 240 VAC, 50/60 Hz D in model number: 24 VAC, 50/60 Hz; 24 VDC
Operating voltage range 85 to 110% of rated supply voltage
Power consumption Models with option selection of 000:7.0 VA max. at 100 to 240 VAC, and 4.2 VA max. at 24 VAC or 2.4 W max. at 24 VDC All other models: 9.0 VA max. at 100 to 240 VAC, and 5.6 VA max. at 24 VAC or 3.4 W max. at 24 VDC
Sensor input Temperature input Thermocouple: K, J, T, E, L, U, N, R, S, B, C/W, or PL II Platinum resistance thermometer: Pt100 or JPt100 Infrared temperature sensor (ES1B): 10 to 70°C, 60 to 120°C, 115 to 165°C, or 140 to 260°C Analog input Current input: 4 to 20 mA or 0 to 20 mA Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V
Input impedance Current input: 150 Ω max., Voltage input: 1 MΩ min. (Use a 1:1 connection when connecting the ES2-HB-N/THB-N.)
Control method ON/OFF or 2-PID control (with auto-tuning)
Control output Relay output SPST-NO, 250 VAC, 5 A (resistive load), electrical life: 100,000 operations, minimum applicable load: 5 V, 10 mA (reference value)
Voltage output (for driving SSR) Output voltage: 12 VDC ± 20% (PNP), max. load current: 40 mA, with short-circuit protection circuit (The maximum load current is 21 mA for models with two control outputs.)
Linear current output 4 to 20 mA DC/0 to 20 mA DC, load: 500 Ω max., resolution: approx. 10,000
Auxiliary output Number of outputs 4
Output specifications SPST-NO. relay outputs, 250 VAC, Models with 2 outputs: 3 A (resistive load), Electrical life: 100,000 operations, Minimum applicable load: 10 mA at 5 V (reference value)
Event input Number of inputs 2, 4 or 6 (depends on model)
External contact input specifications Contact input: ON: 1 kΩ max., OFF: 100 kΩ min.
Non-contact input: ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max.
Current flow: Approx. 7 mA per contact
Transfer output Number of outputs 1 (only on models with a transfer output)
Output specifications Current output: 4 to 20 mA DC, Load: 500 Ω max., Resolution: Approx. 10,000 Linear voltage output: 1 to 5 VDC, load: 1 kΩ min., Resolution: Approx. 10,000
Remote SP input Current input: 4 to 20 mA DC or 0 to 20 mA DC (input impedance: 150 Ω max.) Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V (input impedance: 1 MΩ min.)
Potentiometer input 100 Ω to 10 kΩ
Setting method Digital setting using front panel keys
Indication method 11-segment digital display and individual indicators Character height: PV: 25.0 mm, SV: 15.0 mm, MV: 9.5 mm Three displays Contents: PV/SV/MV, PV/SV/Multi-SP, or PV/SV/Remaining soak time, etc Numbers of digits: 4 digits each for PM, SV, and MV displays
Multi SP Up to eight set points (SP0 to SP7) can be saved and selected using the event inputs, key operations, or serial communications.
Bank switching None
Other functions Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions, heater burnout (HB) alarm (including SSR failure (HS) alarm), 40% AT, 100% AT, MV limiter, input digital filter, self tuning, robust tuning, PV input shift, run/stop, protection functions, extraction of square root, MV change rate limit, logic operations, temperature status display, simple programming, moving average of input value, and display brightness setting
Ambient operating temperature -10 to 55°C (with no condensation or icing), For 3-year warranty: -10 to 50°C with standard mounting (with no condensation or icing)
Ambient operating humidity 25 to 85%
Storage temperature -25 to 65°C (with no condensation or icing)
Altitude 2,000 m max.
Recommended fuse T2A, 250 VAC, time-lag, low-breaking capacity
Installation environment Overvoltage category II, Pollution Degree 2 (EN/IEC/UL 61010-1)
Specifications Details
Indication accuracy (at the ambient temperature of 23°C) Thermocouple: (±0.3% of indication value or ±1°C, whichever is greater) ±1 digit max. *1 Platinum resistance thermometer: (±0.2% of indication value or ±0.8°C, whichever is greater) ±1 digit Analog input: ±0.2% FS ±1 digit max. CT input: ±5% FS ±1 digit max. Potentiometer input: ±5% FS ±1 digit max.
Transfer output accuracy ± 0.3% FS max.
Remote SP Input Type ± 0.2% FS ± 1 digit max.
Influence of temperature *2 Thermocouple input (R, S, B, C/W, PL II): (±1% of indication value or ±10°C, whichever is greater) ±1 digit max. Other thermocouple input: (±1% of indication value or ±4°C, whichever is greater) ±1 digit max. *3 Platinum resistance thermometer: (±1% of indication value or ±2°C, whichever is greater) ±1 digit max. Analog input: ±1%FS ±1 digit max. CT input: ±5% FS ±1 digit max. Remote SP input: ±1% FS ±1 digit max.
Influence of voltage *2
Influence of EMS. (at EN 61326-1)
Input sampling period 50ms
Hysteresis Temperature input: 0.1 to 999.9°C or °F (in units of 0.1°C or°F) Analog input: 0.01% to 99.99% FS (in units of 0.01% FS)
Proportional band (P) Temperature input: 0.1 to 999.9°C or °F (in units of 0.1°C or °F) Analog input: 0.1 to 999.9% FS (in units of 0.1% FS)
Integral time (I) Standard, heating/cooling, or Position-proportional (Close): 0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) Position-proportional (Floating): 1 to 9999 s (in units of 1 s), 0.1 to 999.9 s (in units of 0.1 s) *4
Derivative time (D) 0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *4
Proportional band (P) for cooling Temperature input: 0.1 to 999.9°C or °F (in units of 0.1°C or °F) Analog input: 0.1 to 999.9% FS (in units of 0.1% FS)
Integral time (I) for cooling 0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *4
Derivative time (D) for cooling 0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *4
Control period 0.1, 0.2, 0.5, 1 to 99 s (in units of 1 s)
Manual reset value 0.0 to 100.0% (in units of 0.1%)
Alarm setting range -1999 to 9999 (decimal point position depends on input type)
Influence of signal source resistance Thermocouple: 0.1°C/Ω max. (100 Ω max.) Platinum resistance thermometer: 0.1°C/Ω max. (10 Ω max.)
Insulation resistance 20 MΩ min. (at 500 VDC)
Dielectric strength 3,000 VAC, 50/60 Hz for 1 min between terminals of different charge
Vibration Malfunction 10 to 55 Hz, 20 m/s² for 10 min each in X, Y, and Z directions
Resistance 10 to 55 Hz, 20 m/s² for 2 hrs each in X, Y, and Z directions
Shock Malfunction 100 m/s², 3 times each in X, Y, and Z directions
Resistance 300 m/s², 3 times each in X, Y, and Z directions
Weight Controller: Approx. 250 g, Mounting Adapter: Approx. 4 g × 2
Degree of protection Front panel: IP66, Rear case: IP20, Terminals: IP00
Memory protection Non-volatile memory (number of writes: 1,000,000 times)
Setup Tool CX-Thermo version 4.5 or higher
Setup Tool port E5AC top panel: An E58-CIFQ2 USB-Serial Conversion Cable is used to connect to a USB port on the computer. *5 E5AC front panel: An E58-CIFQ2 USB-Serial Conversion Cable and E58-CIFQ2-E Conversion Cable are used together to connect to a USB port on the computer. *5
Standards Approved standards cULus: UL 61010-1/CSA C22.2 No.61010-1, Korean wireless regulations (Radio law: KC Mark) (Some models only.) *6, Lloyd's standards *7
Conformed standards EN 61010-1 (IEC 61010-1), RCM
EMC EMI EN 61326-1 *8 Radiated Interference Electromagnetic Field Strength: EN 55011 Group 1, class A Noise Terminal Voltage: EN 55011 Group 1, class A EMS: EN 61326-1 *8 ESD Immunity: EN 61000-4-2 Electromagnetic Field Immunity: EN 61000-4-3 Burst Noise Immunity: EN 61000-4-4 Conducted Disturbance Immunity: EN 61000-4-6 Surge Immunity: EN 61000-4-5 Voltage Dip/Interrupting Immunity: EN 61000-4-11
Model Control outputs 1 and 2 No. of auxiliary outputs Power supply voltage Terminal type Input type Options Meaning
Output 1 Output 2
E5EC 48 x 96 mm
E5AC 96 x 96 mm
RX Relay output None
QX Voltage output (for driving SSR) None
CX Linear current output None *2
QQ Voltage output (for driving SSR) Voltage output (for driving SSR)
QR Voltage output (for driving SSR) Relay output
RR Relay output Relay output
CC Linear current output Linear current output *2
CQ Linear current output Voltage output *2
PR Position-proportional relay output
4 (auxiliary outputs 1 and 2 with same common and auxiliary outputs 3 and 4 with same common) *3
100 to 240 VAC A
24 VAC/DC D
Screw terminal blocks (with cover) 5
Universal input M
Catalog Name
Catalog Number[size]
Last Update
E5C, E5C-T Data Sheet H177-E1-16
[40802KB]
Dec 01, 2023
E5C Brochure H220-E1-04
[4605KB]
Oct 02, 2023

Applications

  • Packaging machines
  • Plastic processing
  • Food & beverage production
  • Ovens and dryers
  • HVAC and thermal chambers
  • Scientific and lab instruments

Why Choose

  • Ideal for general-purpose and high-demand control applications
  • High clarity display reduces operator error
  • Quick setup with USB and parameter backup functions
  • Industry-leading reliability and long-term support

Inquiry Now

Brands

Global Brands We Represent in Automation & Switchgear

Scan the QR to call