Omron E5CSL Series Temperature Controller
The Omron E5CSL is the most basic member of Omron's E5□L temperature controller family: a 1/16 DIN (48 × 48 mm) unit with a single large display, one control output and no alarm output. Its 21.7 mm digits are the tallest in the range, so the reading is clear even from a few metres away, and the 60 mm depth behind the panel suits shallow OEM enclosures. Pick the E5CSL when a machine simply needs one heating point held steady with ON/OFF or auto-tuned PID control, and no separate alarm contact is required.
Categories:
Panel ComponentsKey Features
- Single display with 21.7 mm characters, the largest in the E5CSL / E5CWL / E5EWL range, for easy reading at a distance
- No alarm output on any E5CSL model, which keeps terminal wiring and the parameter list as short as possible
- Choice of relay output (SPST-NO, 250 VAC, 3 A) for contactors or 12 VDC voltage output to switch a solid state relay
- Separate versions for thermocouple (K, J, T, R, S) and Pt100 sensors
- ON/OFF control, or 2-PID control with auto-tuning when tighter regulation is needed
- Only 60 mm deep behind the panel, with a 250 ms sampling period
| Specifications | Details | |
|---|---|---|
| Power supply voltage | 100 to 240 VAC, 50/60 Hz | |
| Operating voltage range | 85% to 110% of rated supply voltage | |
| Power consumption | 3.5 VA | |
| Sensor input | Models with thermocouple inputs
Thermocouple: K, J, T, R, or S |
|
| Models with platinum resistance thermometer inputs
Platinum resistance thermometer: Pt100 |
||
| Control
output |
Relay output | SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations,
minimum load: 5 V, 10 mA |
| Voltage output
(for driving SSR) |
Output voltage: 12 VDC +25%/-15% (PNP), max. load current: 21 mA, with short-
circuit protection circuit |
|
| Alarm output * | SPST-NO, 250 VAC, 1 A (resistive load), electrical life: 100,000 operations, minimum load: 5 V, 10 mA | |
| Control method | ON/OFF control or 2-PID control (with auto-tuning) | |
| Setting method | Digital setting using front panel keys | |
| Indication method | 7-segment digital display and individual indicators
Character height: E5CSL: 21.7 mm, E5CWL: 16.2 mm (PV), E5EWL: 20 mm (PV) |
|
| Other functions | Temperature input shift, run/stop, protection functions, etc. | |
| Ambient operating temperature | -10 to 55°C (with no icing or condensation) | |
| Ambient operating humidity | 25% to 85% | |
| Storage temperature | -25 to 65°C (with no icing or condensation) | |
| Specifications | Details | |
|---|---|---|
| Indication accuracy | Thermocouple: (See note 1.)
(±0.5% of indicated value or ±1°C, whichever is greater) ±1 digit max. Platinum resistance thermometer: (±0.5% of indicated value or ±1°C, whichever is greater) ±1 digit max. |
|
| Influence of temperature | R and S thermocouple inputs:
(±1% of PV or ±10°C, whichever is greater) ±1 digit max. K, J, and T thermocouple inputs: (±1% of PV or ±4°C, whichever is greater) ±1 digit max. Platinum resistance thermometer inputs: (±1% of PV or ±2°C, whichever is greater) ±1 digit max. |
|
| Influence of voltage | ||
| Influence of EMS. (at EN61326-1) | ||
| Hysteresis | 0.1 to 999.9 (in units of 0.1) °C/°F | |
| Proportional band (P) | 0.1 to 999.9 (in units of 0.1) °C/°F | |
| Integral time (I) | 0 to 3999 s (in units of 1 s) | |
| Derivative time (D) | 0 to 3999 s (in units of 1 s) | |
| Control period | 0.5, 1 to 99 s (in units of 1 s) | |
| Alarm setting range | -1999 to 9999 (decimal point position depends on input type) | |
| Sampling period | 250 ms | |
| Affect of signal source resistance | Thermocouple: 0.1°C/Ω max. (100 Ω max.) (See note 2.)
Platinum resistance thermometer: 0.6°C/Ω max. (10 Ω max.) |
|
| Insulation resistance | 20 MΩ min. (at 500 VDC) | |
| Dielectric strength | 2,300 VAC, 50 or 60 Hz for 1 min (between terminals with different charge) | |
| Vibration resistance | Malfunction | 10 to 55 Hz, 20 m/s2 for 10 min each in X, Y, and Z directions |
| Destruction | 10 to 55 Hz, 20 m/s2 for 2 hrs each in X, Y, and Z directions | |
| Shock resistance | Malfunction | 100 m/s2 min., 3 times each in X, Y, and Z directions |
| Destruction | 300 m/s2 min., 3 times each in X, Y, and Z directions | |
| Weight | E5CSL/E5CWL | Controller: Approx. 100 g, Mounting Bracket: Approx. 10 g |
| E5EWL | Controller: Approx. 150 g, Mounting Bracket: Approx. 10 g | |
| Degree of protection | Front panel: IP50
Rear case: IP20, Terminals: IP00 |
|
| Memory protection | Non-volatile memory (number of writes: 100,000 times) | |
| Conformed standards | EN61326-1 (See note 3.), EN61010-1, IEC61010-1
VDE0106 Part 100 (Finger protection), when the terminal cover is mounted. |
|
| EMC | Emission Enclosure: EN55011 Group1 Class A
Emission AC Mains: EN55011 Group1 Class A Immunity ESD: EN61000-4-2 Immunity RF-interference: EN61000-4-3 10 V/m Immunity Conducted Disturbance: EN61000-4-6 3 V Immunity Burst: EN61000-4-4 Immunity Surge: EN61000-4-5 Immunity Voltage Dip/Interrupting: EN61000-4-11 |
|
| Size | Power Supply Voltage | Input Type | Alarm Output | Control Output | Model |
|---|---|---|---|---|---|
|
1/16 DIN 48 × 48 × 60 (W × H × D) |
100 to 240 VAC | Thermocouple | None | Relay output | E5CSL-RTC |
| Resistance thermometer | E5CSL-RP | ||||
| Thermocouple | Voltage output (for driving SSR) | E5CSL-QTC | |||
| Resistance thermometer | E5CSL-QP | ||||
|
1/16 DIN 48 × 48 × 60 (W × H × D) |
100 to 240 VAC | Thermocouple | 1 | Relay output | E5CWL-R1TC |
| Resistance thermometer | E5CWL-R1P | ||||
| Thermocouple | Voltage output (for driving SSR) | E5CWL-Q1TC | |||
| Resistance thermometer | E5CWL-Q1P | ||||
|
1/8 DIN 48 × 96 × 60 (W × H × D) |
100 to 240 VAC | Thermocouple | 1 | Relay output | E5EWL-R1TC |
| Resistance thermometer | E5EWL-R1P | ||||
| Thermocouple | Voltage output (for driving SSR) | E5EWL-Q1TC | |||
| Resistance thermometer | E5EWL-Q1P |
|
Catalog Name
|
Catalog Number[size]
|
Last Update
|
|---|---|---|
| E5CSL, E5CWL, E5EWL Data Sheet | H167-E1-03 [1802KB] |
Sep 11, 2023 |
Where the E5CSL Fits Best
Many heating jobs on a machine do not need alarms, communication or ramp programs. They need one sensor, one heater and a number the operator can trust. The E5CSL is built for exactly that. Every model in the E5CSL line-up (E5CSL-RTC, E5CSL-RP, E5CSL-QTC and E5CSL-QP) has the alarm output column marked "None", so the controller does one job: compare the measured value with the set point and switch the heater.
Because there is no alarm relay to configure, commissioning is quick. An electrician selects the input type, enters the set point and, if the load needs it, runs auto-tuning to switch from ON/OFF to 2-PID control. For OEMs building a batch of identical machines, this short setup routine reduces the chance of a wrong setting reaching the customer.
The large single display is the other reason buyers choose this model. With 21.7 mm characters, the process value can be read from the walkway without opening the panel door, which is useful on long machines or where the panel is mounted high.
Applications
- Heat sealing and pouch packing machines: one heater bar per controller, with the voltage output driving an SSR for frequent switching
- Small ovens, dryers and hot-air blowers: single-zone heating where an ON/OFF or PID loop is enough
- Water, oil and wax heating tanks: Pt100 versions for steady low-range temperature holding
- Plastic welding and hot-plate equipment: K or J thermocouple versions with the relay output switching a heater contactor
- Replacing older single-loop controllers: the 1/16 DIN 48 × 48 mm size fits existing panel cut-outs of the same format
Why Choose the E5CSL
- Lowest wiring and setup effort in the series, since there is no alarm output to connect or program
- Largest digit height (21.7 mm) of the three E5□L models listed on this page
- Same sensor choices, control outputs and 250 ms sampling as its siblings, so control quality is not compromised
- Settings are held in non-volatile memory, rated for 100,000 writes
E5CSL or E5CWL?
Both controllers share the same 48 × 48 × 60 mm body, power supply (100 to 240 VAC) and control functions. The difference is the alarm. If your process must raise a separate signal on over-temperature or deviation, for example to sound a hooter or stop a feeder, the Omron E5CWL temperature controller adds one alarm output and shows the process value with 16.2 mm characters. If no alarm contact is needed, the E5CSL is the simpler and cleaner choice. Our team in Ahmedabad and Morbi can help you match the correct E5CSL model code to your sensor and heater.