Omron E5CWL Series Temperature Controller
The Omron E5CWL is a 1/16 DIN (48 × 48 mm) digital temperature controller that adds what many process heaters need: one alarm output and a two-line display that shows the process value and set point at the same time. The PV is shown in 16.2 mm characters, while the alarm relay (SPST-NO, 250 VAC, 1 A) can warn the operator or trip an interlock when the temperature moves outside the limit you set. It is the right pick for ovens, moulding heaters and heating tanks where an out-of-range temperature must be flagged, not just controlled.
Categories:
Panel ComponentsKey Features
- One alarm output on every E5CWL model: SPST-NO, 250 VAC, 1 A (resistive load)
- Alarm set value adjustable from -1999 to 9999, so limits can be set for high, low or deviation conditions
- PV and SV visible together; process value shown in 16.2 mm characters
- Control output as relay (3 A at 250 VAC) or 12 VDC pulse to drive an SSR (models R1 and Q1)
- Thermocouple K, J, T, R or S versions, plus Pt100 resistance thermometer versions
- ON/OFF or 2-PID with auto-tuning, 250 ms sampling and only 60 mm depth behind the panel
| Specifications | Details | |
|---|---|---|
| Power supply voltage | 100 to 240 VAC, 50/60 Hz | |
| Operating voltage range | 85% to 110% of rated supply voltage | |
| Power consumption | 3.5 VA | |
| Sensor input | Models with thermocouple inputs
Thermocouple: K, J, T, R, or S |
|
| Models with platinum resistance thermometer inputs
Platinum resistance thermometer: Pt100 |
||
| Control
output |
Relay output | SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations,
minimum load: 5 V, 10 mA |
| Voltage output
(for driving SSR) |
Output voltage: 12 VDC +25%/-15% (PNP), max. load current: 21 mA, with short-
circuit protection circuit |
|
| Alarm output * | SPST-NO, 250 VAC, 1 A (resistive load), electrical life: 100,000 operations, minimum load: 5 V, 10 mA | |
| Control method | ON/OFF control or 2-PID control (with auto-tuning) | |
| Setting method | Digital setting using front panel keys | |
| Indication method | 7-segment digital display and individual indicators
Character height: E5CSL: 21.7 mm, E5CWL: 16.2 mm (PV), E5EWL: 20 mm (PV) |
|
| Other functions | Temperature input shift, run/stop, protection functions, etc. | |
| Ambient operating temperature | -10 to 55°C (with no icing or condensation) | |
| Ambient operating humidity | 25% to 85% | |
| Storage temperature | -25 to 65°C (with no icing or condensation) | |
| Specifications | Details | |
|---|---|---|
| Indication accuracy | Thermocouple: (See note 1.)
(±0.5% of indicated value or ±1°C, whichever is greater) ±1 digit max. Platinum resistance thermometer: (±0.5% of indicated value or ±1°C, whichever is greater) ±1 digit max. |
|
| Influence of temperature | R and S thermocouple inputs:
(±1% of PV or ±10°C, whichever is greater) ±1 digit max. K, J, and T thermocouple inputs: (±1% of PV or ±4°C, whichever is greater) ±1 digit max. Platinum resistance thermometer inputs: (±1% of PV or ±2°C, whichever is greater) ±1 digit max. |
|
| Influence of voltage | ||
| Influence of EMS. (at EN61326-1) | ||
| Hysteresis | 0.1 to 999.9 (in units of 0.1) °C/°F | |
| Proportional band (P) | 0.1 to 999.9 (in units of 0.1) °C/°F | |
| Integral time (I) | 0 to 3999 s (in units of 1 s) | |
| Derivative time (D) | 0 to 3999 s (in units of 1 s) | |
| Control period | 0.5, 1 to 99 s (in units of 1 s) | |
| Alarm setting range | -1999 to 9999 (decimal point position depends on input type) | |
| Sampling period | 250 ms | |
| Affect of signal source resistance | Thermocouple: 0.1°C/Ω max. (100 Ω max.) (See note 2.)
Platinum resistance thermometer: 0.6°C/Ω max. (10 Ω max.) |
|
| Insulation resistance | 20 MΩ min. (at 500 VDC) | |
| Dielectric strength | 2,300 VAC, 50 or 60 Hz for 1 min (between terminals with different charge) | |
| Vibration resistance | Malfunction | 10 to 55 Hz, 20 m/s2 for 10 min each in X, Y, and Z directions |
| Destruction | 10 to 55 Hz, 20 m/s2 for 2 hrs each in X, Y, and Z directions | |
| Shock resistance | Malfunction | 100 m/s2 min., 3 times each in X, Y, and Z directions |
| Destruction | 300 m/s2 min., 3 times each in X, Y, and Z directions | |
| Weight | E5CSL/E5CWL | Controller: Approx. 100 g, Mounting Bracket: Approx. 10 g |
| E5EWL | Controller: Approx. 150 g, Mounting Bracket: Approx. 10 g | |
| Degree of protection | Front panel: IP50
Rear case: IP20, Terminals: IP00 |
|
| Memory protection | Non-volatile memory (number of writes: 100,000 times) | |
| Conformed standards | EN61326-1 (See note 3.), EN61010-1, IEC61010-1
VDE0106 Part 100 (Finger protection), when the terminal cover is mounted. |
|
| EMC | Emission Enclosure: EN55011 Group1 Class A
Emission AC Mains: EN55011 Group1 Class A Immunity ESD: EN61000-4-2 Immunity RF-interference: EN61000-4-3 10 V/m Immunity Conducted Disturbance: EN61000-4-6 3 V Immunity Burst: EN61000-4-4 Immunity Surge: EN61000-4-5 Immunity Voltage Dip/Interrupting: EN61000-4-11 |
|
| Size | Power Supply Voltage | Input Type | Alarm Output | Control Output | Model |
|---|---|---|---|---|---|
|
1/16 DIN 48 × 48 × 60 (W × H × D) |
100 to 240 VAC | Thermocouple | None | Relay output | E5CSL-RTC |
| Resistance thermometer | E5CSL-RP | ||||
| Thermocouple | Voltage output (for driving SSR) | E5CSL-QTC | |||
| Resistance thermometer | E5CSL-QP | ||||
|
1/16 DIN 48 × 48 × 60 (W × H × D) |
100 to 240 VAC | Thermocouple | 1 | Relay output | E5CWL-R1TC |
| Resistance thermometer | E5CWL-R1P | ||||
| Thermocouple | Voltage output (for driving SSR) | E5CWL-Q1TC | |||
| Resistance thermometer | E5CWL-Q1P | ||||
|
1/8 DIN 48 × 96 × 60 (W × H × D) |
100 to 240 VAC | Thermocouple | 1 | Relay output | E5EWL-R1TC |
| Resistance thermometer | E5EWL-R1P | ||||
| Thermocouple | Voltage output (for driving SSR) | E5EWL-Q1TC | |||
| Resistance thermometer | E5EWL-Q1P |
|
Catalog Name
|
Catalog Number[size]
|
Last Update
|
|---|---|---|
| E5CSL, E5CWL, E5EWL Data Sheet | H167-E1-03 [1802KB] |
Sep 11, 2023 |
What the Alarm Output Adds
In a heating process, holding the set point is only half the requirement. Plant engineers also want to know when something has gone wrong: a heater element has failed, a contactor has welded shut, or a door has been left open and the chamber is cooling. The E5CWL handles this with a dedicated alarm relay, separate from the control output, so a warning lamp, buzzer or interlock relay can be wired directly to the controller without an extra temperature switch.
All four catalogue models carry one alarm: E5CWL-R1TC and E5CWL-R1P with relay control output, and E5CWL-Q1TC and E5CWL-Q1P with voltage output for SSR drive. The "TC" versions accept K, J, T, R or S thermocouples, which covers everything from low-temperature tanks up to high-temperature points measured with R or S sensors; the "P" versions take a Pt100 for better resolution in the lower range.
The two-line display is useful during start-up and batch changes. The operator sees the actual temperature and the target together, so it is obvious whether the process is still heating up or has settled, without pressing any key.
Applications
- Industrial ovens and curing chambers: the alarm relay can switch off the heater circuit or sound a hooter on over-temperature
- Injection moulding and extruder heater zones: PV and SV visible side by side on each zone controller
- Thermic fluid and hot oil heaters: high-limit warning in addition to normal temperature control
- Dryers and auxiliary heating points in ceramic and tile plants: R or S thermocouple versions for high-temperature measurement
- Food and dairy jacketed vessels: deviation alarm when the batch drifts away from its holding temperature
For more real-world examples, read our article on E5CWL applications in industrial automation.
Why Choose the E5CWL
- Control and alarm in one 48 × 48 mm unit, saving panel space and a separate limit device
- Alarm contact rated 1 A at 250 VAC, suitable for indicators and interlock relays
- Operator can see actual and target temperature at a glance
- Same compact 60 mm depth and 100 to 240 VAC supply as the rest of the E5□L range
E5CWL or E5CSL?
The Omron E5CSL temperature controller uses the same 1/16 DIN housing and control functions but has no alarm output and a single display with larger 21.7 mm digits. Choose the E5CSL for simple single-point heating where a bigger number matters more than an alarm. Choose the E5CWL whenever the process needs a warning or interlock signal, or when operators should see the set point and the actual value together. If you are unsure which suffix (R1 or Q1, TC or P) suits your heater and sensor, share the details with our Ahmedabad or Morbi team.