Trajpar, NH-8A, Morbi, Gujarat
GST No. 24AAECV0377J1Z8
Call 08047310184 75% Response Rate
Product Brochure
Model Name/Number | PM600 |
Capacity | 500VA TO 3000VA |
Usage/Application | Industrial |
Battery Type | DRY |
Phase | 3 |
Protection | OverVoltage |
Back Up Time | 10-20 Mins |
Country of Origin | Made in India |
View Complete details
Product Brochure
Number Of Ports | 3 |
Usage/Application | Industrial |
Network Type | RS-232 |
Model Name/Number | IDA-PA124PL |
Terminator for RS- | 232 ,485 |
ProstarM provides reliable and high-performing Modbus card for UPS. The conversion card can be used to connect the UPS to the RS485 trunk to accomplish the integrated management of different devices. Our Modbus cards for UPS come with reliable security and communication features enabling the user to Use Modbus protocol to communicate with protocol conversion equipment through RS485 and accomplish the conversion between UPS EA protocol and Modbus/RS485/TCPIP.
Distributed UPS Centralized Monitoring & Management Solution
Distributed UPS centralized monitoring and management solution, it solve the difficulty of centralized monitoring & management which have multiple branches or with wide distribution, also provide administrators with an efficient, safety, stable and intelligent monitoring & management platform.
View Complete details
Product Brochure
Brand | PROSTAR M |
Model Name/Number | PM900-PRO |
Capacity | 10-20 KVA |
Input Voltage | 380/400/415 |
Output Voltage | 380/400/415 |
Configuration | 3 Phase IN - 3 Phase OUT |
Efficiency | 95 |
Form Factor | Tower Model |
Audible Noise | +-5 |
Display Type | LED |
Back Up Time | 10-20 Mins |
Storage Temperature | 70 |
Battery Backup | 15 |
Battery Rating | 26 AH |
Solar Power Compatable | No |
View Complete details
Product Brochure
Brand | PROSTAR M |
Model Name/Number | PM890 IR Series |
Capacity | 80 TO 500 KVA |
Input Voltage | 380/400/415 |
Output Voltage | 380/400/415 |
Configuration | 3 Phase IN - 3 Phase OUT |
Efficiency | 95 |
Form Factor | Tower Model |
Back Up Time | 10-20 Mins |
Storage Temperature | 70 |
Battery Backup | 15 |
Battery Rating | 150 AH |
View Complete details
Product Brochure
Model Name/Number | PM800 |
Capacity | 10 TO 30KVA |
Usage/Application | Industrial |
Battery Type | DRY |
Phase | 3 |
Protection | OverVoltage |
Type | Online UPS |
Galvanic isolation
In transformer based UPS system, the transformer works to step up the voltage at the inverter output, bringing it to a level that is compatible to generator supply voltage or the utility. However, the transformer is not exactly used to provide galvanic isolation. In case a total galvanic isolation is needed, in an isolation transformer UPS or a transformer-less UPS, an additional transformer is required in the circuit. The transformer should also have adequate insulation to prevent the high voltage in UPS output jumping between the windings. This also helps prevent a net DC output component.
Input isolation between mains and battery
This type of isolation is rare in modern times. It was found in early 1960s when open lead-acid batteries were commonplace. After maintenance-free lead-acid batteries and nickel-cadmium batteries came into use in 1980s, the use of input isolation in UPS systems saw a drastic decline.
DC component output isolation in online UPS with isolation transformer
In isolation transformer online UPS systems, the transformer isolates the DC circuit from the output load apart from stepping up the inverter output voltage. Thus it works to isolate the DC component generated by an inverter fault. However, the DC component generated by the inverter could reach the load if a bypass component fails. This is because in such a case, the bypass supply does not pass through the transformer, which is a drawback of the isolation transformer based UPS system.
Benefits of isolation transformer in UPS system
Online UPS with isolation transformer isolates the load from power source and provides better protection from power surges. Isolation transformers also help convert the voltage to a level best suited for the load. This is especially necessary if the voltage of the UPS system differs from the voltage requirement of the load. An isolation transformer can step the voltage up of down according
to the need of the load. Inbuilt isolation transformers within the UPS system also help reduce fault
current, enabling smooth working of the connected equipment Isolation transformer have played a big role in data centre UPS systems. In data centers, online UPS with isolation transformer are a part of power conversion circuit. The UPS systems serve to reduce harmonics, efficiently resolve ground loops with multiple generators or mains sources, and help tackle high or low voltage issue.
View Complete details
Product Brochure
Type | Online |
Brand | TMAIC |
Model Name/Number | W250 Series |
Usage/Application | Industrial |
Battery Type | SMF/VRLA |
Phase | 3 |
Protection | ALL TYPE |
Weight | 550kg |
Dimension | 700 x 832 x 2080 |
View Complete details
Product Brochure
Type | Online UPS |
Model Name/Number | PM890 |
Capacity | 50 TO 800 KVA |
Usage/Application | Industrial |
Battery Type | DRY |
Phase | 3 |
Protection | OverVoltage |
View Complete details
Product Brochure
Type | Online |
Brand | PROSTAR M |
Model Name/Number | HT10K |
Usage/Application | Industrial |
Battery Type | SMF/ Tubular/ Lithium ion |
Phase | 3 phase input 3 phase output |
Protection | OverVoltage |
View Complete details
Filled Weight | 20 TO 60 KG |
Warranty | 2 YEAR |
Voltage | 12V & 24V |
Model Name/Number | EP 65-12 |
View Complete details
Warranty | 2 YEAR |
Voltage | 12V |