ABB Formula DSP Series MCCB Switchgear
The ABB Formula DSP (Digital Smart Protection) MCCB series offers advanced digital protection and monitoring for industrial and commercial electrical systems. Designed to provide precise fault detection, enhanced diagnostics, and improved system reliability, Formula DSP MCCBs are ideal for modern smart grids and automation systems.
Categories:
ABB SwitchgearKey Features
- Digital Trip Unit Technology:
– Provides accurate protection with adjustable settings for overload, short circuit, ground fault, and more.
– Advanced diagnostics and fault recording capabilities. - Smart Monitoring & Communication:
– Integrated communication protocols including Modbus, Profibus, and Ethernet.
– Remote monitoring and control for predictive maintenance and system optimization. - High Breaking Capacity:
– Interrupts short circuits up to 150 kA (model dependent). - Wide Current Ratings:
– Available from 16 A to 1600 A for versatile applications. - Compact and Modular Design:
– Fits easily into switchgear panels, with accessory modules for enhanced functionality. - User-Friendly Interface:
– Clear LCD display for real-time data visualization.
– Simple configuration and status indication. - Global Compliance:
– Certified to IEC/EN 60947-2, UL, CSA standards.
| Parameter | Description | Formula / Definition | Notes |
|---|---|---|---|
| Discrimination Selectivity Protection (DSP) | Ensures selective tripping of downstream MCCBs without affecting upstream breakers | N/A (Conceptual protection scheme) | Prevents unnecessary power outages by coordinating breakers |
| Time Selectivity | Downstream breaker trips before upstream breaker by time delay | Tupstream > Tdownstream + ΔT | ΔT = safety margin (typically 0.2 to 0.5 seconds) |
| Current Selectivity | Downstream breaker trips at lower fault current than upstream breaker | Itrip downstream < Itrip upstream | Ensures only closest breaker to fault trips |
| Energy Let-Through Coordination | Coordination of I²t values to prevent upstream breaker tripping | I2tupstream > I2tdownstream | Helps in discrimination during short-duration faults |
| Selectivity Ratio | Ratio of upstream to downstream breaking capacities | SR = Icu upstream / Icu downstream | Ideal SR > 1 for effective discrimination |
| Motor | Moulded case circuit breakers | Contactor | Overload relay | ||||
|---|---|---|---|---|---|---|---|
| Rated power [kW] |
Rated current [A] |
Type | Instantaneous tripping current [A] | Type | Type | Current setting range [A] | |
| 0.37 | 1.1 | XT2S160 MF 2 | 28 | A9 | TA25DU1.4 | 1 - 1.4 | |
| 0.55 | 1.5 | XT2S160 MF 2 | 28 | A9 | TA25DU1.8 | 1.3 - 1.8 | |
| 0.75 | 1.9 | XT2S160 MF 2 | 28 | A9 | TA25DU2.4 | 1.7 - 2.4 | |
| 1.1 | 2.7 | XT2S160 MF 4 | 56 | A9 | TA25DU4 | 2.8 - 4 | |
| 1.5 | 3.6 | XT2S160 MF 4 | 56 | A16 | TA25DU5 | 3.5 - 5 | |
|
Catalog Name
|
Catalog Number[size]
|
Last Update
|
|---|---|---|
| Sace Formula Dsp Data Sheet | --- [230kb] |
--- |
Applications
- Industrial power distribution and control
- Commercial and infrastructure electrical systems
- Motor control centers (MCCs)
- Renewable energy systems
- Data centers and critical power installations
Why Choose
- Formula Safe Protection technology enhances safety for operators.
- Flexible trip units for customized protection.
- Compact size saves panel space without compromising performance.
- Integrated communication options for smart monitoring and control.
- Trusted ABB quality with global certifications and support.