Omron CJ1W Programmable Logic Controller
The Omron CJ1W series includes a wide range of I/O, communication, analog, temperature, and special function modules designed to seamlessly integrate with Omron CJ1M, CJ2M, and CJ2H PLCs. Built to meet diverse industrial automation needs, CJ1W modules offer scalable, high-performance solutions in a compact, modular format.
Categories:
Omron CJ Series PLC- Select the best interface for each application: Fujitsu / OTAX connectors and MIL connectors.
- Select sinking outputs or sourcing outputs. The CJ1W-MD232 has load short-circuit protection.
- The ON and OFF response times can be set to between 0 and 32 ms in the Setup in the CPU Unit.
- Mixed I/O Units with 5-V TTL inputs are also available. *
- A wide variety of Connector-Terminal Block Conversion Units are available to allow you to easily wire external I/O devices.
- * Applies to the CJ1W-MD563.
| Specification | Description | ||
|---|---|---|---|
| Name | 16-point DC Input/16-point Transistor Output Unit with Fujitsu / OTAX Connectors (Sinking Outputs) | ||
| Model | CJ1W-MD231 | ||
| Output section (CN1) | Input section (CN2) | ||
| Rated Voltage | 12 to 24 VDC | Rated Input Voltage | 24 VDC |
| Operating Load Voltage Range | 10.2 to 26.4 VDC | Operating Input Voltage | 20.4 to 26.4 VDC |
| Maximum Load Current | 0.5 A/point, 2.0 A/Unit | Input Impedance | 3.3 kΩ |
| Maximum Inrush Current | 4.0 A/point, 10 ms max. | Input Current | 7 mA typical (at 24 VDC) |
| Leakage Current | 0.1 mA max. | ON Voltage/ON Current | 14.4 VDC min./3 mA min. |
| Residual Voltage | 1.5 V max. | OFF Voltage/OFF Current | 5 VDC max./1 mA max. |
| ON Response Time | 0.1 ms max. | ON Response Time | 8.0 ms max. (Can be set to between 0 and 32 in the Setup.) * |
| OFF Response Time | 0.8 ms max. | ||
| No. of Circuits | 16 (16 points/common, 1 circuit) | OFF Response Time | 8.0 ms max. (Can be set to between 0 and 32 in the Setup.) * |
| Fuse | None | ||
| External Power Supply | 10.2 to 26.4 VDC, 20 mA min. | No. of Circuits | 16 (16 points/common, 1 circuit) |
| Number of Simultaneously ON Points | 75% (at 24 VDC) | ||
| Insulation Resistance | 20 MΩ min. between the external terminals and the GR terminal (at 100 VDC) | ||
| Dielectric Strength | 1,000 VAC between the external terminals and the GR terminal for 1 minute at a leakage current of 10 mA max. | ||
| Internal Current Consumption | 5 VDC 130 mA max. | ||
| Weight | 90 g max. | ||
| Accessories | None | ||
| Circuit Configuration | CN1 (OUT) | CN2 (IN) | |
| The signal names of the terminals are the device variable names. The device variable names are the names that use "Jxx" as the device name. | The signal names of the terminals are the device variable names. The device variable names are the names that use "Jxx" as the device name. | ||
| External connection and terminal-device variable diagram | CN1 (OUT) | CN2 (IN) | |
| When wiring, pay careful attention to the polarity of the external power supply. The load may operate incorrectly if polarity is reversed. Be sure to wire both pins A9 and B9 (COM0 (0V)) of CN1. Be sure to wire both pins A10 and B10 (+V) of CN1. The signal names of the terminals are the device variable names. The device variable names are the names that use "Jxx" as the device name. | Be sure to wire both pins A9 and B9 (COM1) of CN2, and set the same polarity for both pins. The signal names of the terminals are the device variable names. The device variable names are the names that use "Jxx" as the device name. | ||
| Function | Specification | ||||||||
|---|---|---|---|---|---|---|---|---|---|
| Type/ Series | Specifications | Model | Stand‑ards | ||||||
| Classification | Po‑lar‑ity | Number of points | Rated ON current at contacts | Rated voltage | |||||
| Push‑In Plus terminal block / G70V | Inputs | DC inputs | NPN | 16 (SPST‑NO × 16) | 50 mA | 24 VDC | G70V‑SID16P *4 | UC, CE (TÜV certified) | |
| PNP | G70V‑SID16P‑1 *4 | ||||||||
| NPN | G70V‑SID16P‑C16 *5 | ||||||||
| PNP | G70V‑SID16P‑1‑C16 *5 | ||||||||
| Outputs | Relay outputs | NPN | 16 (SPDT × 16) | 6 A/point, 10 A/common | G70V‑SOC16P *4 | ||||
| PNP | G70V‑SOC16P‑1 *4 | ||||||||
| NPN | G70V‑SOC16P‑C4 *6 | ||||||||
| PNP | G70V‑SOC16P‑1‑C4 *6 | ||||||||
| Standard / G7TC | Inputs | AC inputs | NPN | 16 (SPST‑NO × 16) | 1 A | 100/110 VAC | G7TC‑IA16 AC100/110 | U, C | |
| 200/220 VAC | G7TC‑IA16 AC200/220 | ||||||||
| DC inputs | 12 VDC | G7TC‑ID16 DC12 | |||||||
| 24 VDC | G7TC‑ID16 DC24 | ||||||||
| 100/110 VDC | G7TC‑ID16 DC100/110 | ||||||||
| Outputs | Relay outputs | NPN | 8 (SPST‑NO × 8) | 5 A | 12 VDC | G7TC‑OC08 DC12 | |||
| 24 VDC | G7TC‑OC08 DC24 | ||||||||
| 16 (SPST‑NO × 16) | 12 VDC | G7TC‑OC16 DC12 | |||||||
| 24 VDC | G7TC‑OC16 DC24 | ||||||||
| PNP | 16 (SPST‑NO × 16) | 12 VDC | G7TC‑OC16‑1 DC12 | ||||||
| 24 VDC | G7TC‑OC16‑1 DC24 | ||||||||
| High‑capacity socket / G70A *1 (Socket only) | Inputs | Relay inputs | NPN/PNP | 16 (SPDT × 16 possible with G2R Relays) | 100 mA | 110 VDC max., 240 VAC max. *2 | G70A‑ZOC16‑5 | U, C, CE (VDE certified) | |
| Outputs | Relay outputs | NPN | 10 A (Terminal block allowable) | 24 VDC | G70A‑ZOC16‑3 | ||||
| PNP | G70A‑ZOC16‑4 | ||||||||
| Space‑saving / Vertical type G70D‑V | Outputs | Relay outputs | NPN | 16 (SPST‑NO × 16) | 5 A or 3 A *3 | 24 VDC | G70D‑VSOC16 | U, C, CE (VDE certified) | |
| MOSFET relay outputs | 0.3 A | G70D‑VFOM16 | |||||||
| Space‑saving / Flat type G70D | Relay outputs | NPN | 8 (SPST‑NO × 8) | 5 A | G70D‑SOC08 | - | |||
| 16 (SPST‑NO × 16) | 3 A | G70D‑SOC16 | |||||||
| PNP | 16 (SPST‑NO × 16) | 3 A | G70D‑SOC16‑1 | ||||||
| MOSFET relay outputs | NPN | 16 (SPST‑NO × 16) | 0.3 A | G70D‑FOM16 | |||||
| PNP | G70D‑FOM16‑1 *7 | ||||||||
| High‑capacity, space‑saving / G70R | Outputs | Relay outputs | NPN | 8 (SPST‑NO × 8) | 10 A | 24 VDC | G70R‑SOC08 *7 | - | |
| Unit type | Product name | Specifications | Current consumption (A) | Model | Standards | |||||
|---|---|---|---|---|---|---|---|---|---|---|
| I/O points | Input voltage and current | Commons | External connection | No. of words allocated | 5 V | 24 V | ||||
| CJ1 Basic I/O Units | DC Input Units | 8 inputs | 12 to 24 VDC, 10 mA | Independent contacts | Removable terminal block | 1 word | 0.09 | --- | CJ1W-ID201 | UC1, N, L, CE |
| 16 inputs | 24 VDC, 7 mA | 16 points, 1 common | Removable terminal block | 1 word | 0.08 | --- | CJ1W-ID211 | |||
| 16 inputs (High speed) | 24 VDC, 7 mA | 16 points, 1 common | Removable terminal block | 1 word | 0.13 | --- | CJ1W-ID212 | N, L, CE | ||
| 32 inputs | 24 VDC, 4.1 mA | 16 points, 1 common | Fujitsu/OTAX connector | 2 words | 0.09 | --- | CJ1W-ID231 | UC1, N, L, CE | ||
| 32 inputs | 24 VDC, 4.1 mA | 16 points, 1 common | MIL connector | 2 words | 0.09 | --- | CJ1W-ID232 | |||
| 32 inputs (High speed) | 24 VDC, 4.1 mA | 16 points, 1 common | MIL connector | 2 words | 0.20 | --- | CJ1W-ID233 | N, L, CE | ||
| 64 inputs | 24 VDC, 4.1 mA | 16 points, 1 common | Fujitsu/OTAX connector | 4 words | 0.09 | --- | CJ1W-ID261 | UC1, N, L, CE | ||
| 64 inputs | 24 VDC, 4.1 mA | 16 points, 1 common | MIL connector | 4 words | 0.09 | --- | CJ1W-ID262 | |||
| AC Input Units | 8 inputs | 200 to 24 VAC, 10 mA (200 V, 50 Hz) | 8 points, 1 common | Removable terminal block | 1 words | 0.08 | --- | CJ1W-IA201 | ||
| 16 inputs | 100 to 120 VAC, 7 mA (100 V, 50 Hz) | 16 points, 1 common | Removable terminal block | 1 words | 0.09 | --- | CJ1W-IA111 | |||
|
Catalog Name
|
Catalog Number[size]
|
Last Update
|
|
|---|---|---|---|
| CJ1W-ID/IA Data Sheet | [3465KB] | Apr 01, 2025 | CJ1W-ID/IA Data Sheet |
| XW2Z-R Data Sheet | G126-E1-04 [2044KB] |
Apr 01, 2025 | XW2Z-R Data Sheet/td> |
| G70V/G7TC/G70A/G70D Table of I/O Relay Terminal and connectable device combinations | J217-E1-04 [1355KB] |
Oct 23, 2023 | G70V/G7TC/G70A/G70D Table of I/O Relay Terminal and connectable device combinations |
| Table of PLC I/O Unit Connection Correspondance | G154-E1-03 [1565KB] |
Apr 01, 2024 | Table of PLC I/O Unit Connection Correspondance |
Applications
- Machine automation
- Material handling systems
- Food and packaging lines
- Temperature-sensitive processes
- Distributed control networks
Why Choose
- Modular plug-and-play architecture
- Easy configuration with Omron CX-One software
- Wide compatibility across CJ-series PLCs
- Reliable operation in industrial environments
- Supports complex systems with precise control and communication
Inquiry Now