Founded in 2012, Shree Vijayvargiya Technologies Pvt. Ltd. is a leading provider of industrial and commercial supplies, specializing in industrial switchgear and automation products. We focus on excellence, innovation, and customer delight across wholesale, distribution, and automation solutions.

Our Socials

Omron Proximity E2K-C Sensor

Omron Proximity E2K-C Sensor Programmable Logic Controller

The Omron E2K-C Series offers reliable capacitive sensing for detecting not only metals but also non-metallic materials such as plastics, glass, wood, powders, liquids, and granules. Designed for versatility and precision, these sensors are perfect for applications where inductive sensors are not sufficient.

  • Capacitive Sensing Technology: Detects a wide range of materials, including non-conductive objects.
  • Adjustable Sensitivity: Built-in sensitivity trimmer allows fine-tuning for target material and distance.
  • Compact Cylindrical Design: Available in M18 housing for easy panel or bracket mounting.
  • DC Operation: Operates on 12 to 24 VDC, suitable for integration with most PLCs and control systems.
  • Output Types: NPN or PNP, Normally Open (NO) configurations for flexible integration.
  • IP66 Protection: Resistant to dust, moisture, and light splashes.
Specification Description
Model E2K-C25M[]1 E2K-C25M[]2 E2K-C25MY1 E2K-C25MY2
Sensing distance * 25 mm
Sensing distance adjustable range 3 to 25 mm
Detectable object Conductors and dielectrics
Standard sensing object Grounded metal plate: 50 × 50 × 1 mm
Differential travel 15% max. of sensing distance (at 25 mm ±10%)
Response frequency 70 Hz 10 Hz
Power supply voltage 12–24 VDC (10–30 VDC), ripple 10% max. 100–220 VAC (90–250 VAC), 50/60 Hz
Current consumption 10 mA max at 12 VDC, 16 mA max at 24 VDC
Leakage current 1–2 mA max depending on voltage (Y Models)
Control output Load current 200 mA max. 5–200 mA (resistive load)
Residual voltage 2 V max. at 200 mA, 2 m cable Refer to datasheet
Indicators Detection indicator (red) Operation indicator (red)
Operation mode (with object approaching) E1/F1/Y1: NO
E2/F2/Y2: NC
See timing charts
Protection circuits Reverse polarity, Surge suppressor Surge suppressor
Ambient temperature -25 to 70°C (no icing/condensation)
Ambient humidity 35% to 95% RH (no condensation)
Temperature influence ±15% (-10 to 55°C), ±25% (-25 to 70°C)
Voltage influence ±2% max at rated voltage ±15% ±2% at 100 VAC (±20%) or 200 VAC (±20%)
Insulation resistance ≥50 MΩ at 500 VDC
Dielectric strength 1,000 VAC, 50/60 Hz, 1 min 1,500 VAC, 50/60 Hz, 1 min
Vibration 10–55 Hz, 1.5 mm amplitude, 2 hrs X/Y/Z
Shock resistance 500 m/s², 10 times in X/Y/Z
Degree of protection IEC 60529 IP66
Connection method Pre-wired (2 m cable)
Weight Approx. 200 g
Materials Case Heat-resistant ABS
Sensing surface Heat-resistant ABS
Accessories Mounting bracket, driver, screws, manual
Function Specification
Model E2K-C20MC1 E2K-C20MC2 E2K-C20MT1 E2K-C20MT2
Sensing distance * 20 mm
Sensing distance adjustable range 3 to 20 mm
Detectable object Conductors and dielectrics
Standard sensing object Grounded metal plate: 50 × 50 × 1 mm
Differential travel 15% max. of sensing distance (when adjusted to 20 mm ±10% with standard sensing object)
Response frequency * 40 Hz AC power: 25 Hz, DC power: 40 Hz
Power supply voltage (operating voltage range) 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max. 24 to 240 VAC (20 to 250 VAC), 50/60 Hz; 24 to 240 VDC (20 to 250 VDC)
Current consumption 13 mA max. at 24 VDC ---
Leakage current --- 1.5 mA max. at 24 VDC, 1.7 mA max. at 110 VAC, 2.5 mA max. at 250 VAC
Control output Load current 250 mA max. 5 to 200 mA (resistive load)
Residual voltage 2.5 V max. (Load current: 250 mA, Cable length: 2 m) AC: 10 V max., DC: 8 V max.
Indicators Operation indicator (yellow)
Operation mode (with sensing object approaching) C1/T1 Models: NO
C2/T2 Models: NC
Protection circuits Reverse polarity, Load short-circuit protection ---
Ambient temperature range -25 to 70°C (no icing/condensation)
Ambient humidity range 35% to 95% RH (no condensation)
Temperature influence ±15% (–10 to 55°C), ±25% (–25 to 70°C)
Voltage influence ±2% max. at rated voltage ±15%
Insulation resistance 50 MΩ min. (500 VDC between live parts and case)
Dielectric strength 1,000 VAC, 50/60 Hz for 1 min 1,500 VAC, 50/60 Hz for 1 min
Vibration resistance 10–55 Hz, 1.5 mm amplitude, 2 hrs each in X/Y/Z
Shock resistance 500 m/s², 10 times each in X/Y/Z directions
Degree of protection IEC 60529 IP65
Connection method * Pre-wired (2 m cable)
Weight (packed) Approx. 240 g
Materials Case PBT
Sensing surface PBT
Accessories Mounting Bracket, M4 screws, Instruction manual
Appearance Sensing
distance
(Adjustable
range)
Output
configuration
Model
Operation mode
NO NC
Standard Models Unshielded 25 mm
(3 to 25 mm)
DC 3-wire, NPN E2K-C25ME1 2M E2K-C25ME2 2M
DC 3-wire, PNP E2K-C25MF1 2M E2K-C25MF2 2M
AC 2-wire E2K-C25MY1 2M *1 E2K-C25MY2 2M
Noise-resistant
Models
20 mm
(3 to 20 mm)
DC 3-wire, NPN E2K-C20MC1 2M E2K-C20MC2 2M
AC/DC 2-wire E2K-C20MT1 2M E2K-C20MT2 2M
Catalog Name
Catalog Number[size]
Last Update
E2K-C Data Sheet --
[991KB]
Nov 11, 2024 E2K-C Data Sheet

Applications

  • Level detection in plastic tanks (water, oil, chemicals)
  • Object detection in packaging, paper, or glass industries
  • Powder flow or hopper monitoring
  • Non-metal conveyor object detection
  • Detection of bottles, caps, or containers in filling lines

Why Choose

  • Detects non-metallic materials that standard inductive sensors can't
  • Ideal for level sensing in tanks, bins, and silos
  • Adjustable range reduces false triggers and improves reliability
  • Trusted Omron quality and compact form factor

Inquiry Now

Brands

Global Brands We Represent in Automation & Switchgear

Scan the QR to call