Fuji Frenic Lift AC Drive
The Fuji FRENIC-Lift AC Drive is engineered specifically for elevator applications, combining high torque performance, precision control, and energy efficiency. It supports both induction and permanent magnet motors and includes built-in braking and PG feedback circuits for enhanced control. With advanced vector control, reduced vibration, and robust communication options like Modbus RTU and CAN Bus, the FRENIC-Lift ensures a smooth, safe, and reliable elevator experience. Its long-life components and flexible feedback compatibility make it a future-proof choice for elevator manufacturers and installers.
Categories:
Fuji AC Drive- Designed exclusively for passenger elevator applications, offering high reliability and smoother operation.
- Built-in braking circuit across all drive capacities for safer elevator control.
- Standard built-in PG feedback circuit enhances precise speed regulation and position control.
- High-performance vector control with current response (ACR) of 500Hz and speed control accuracy of ±0.01%.
- Overload capacity of 200% for 10 seconds (excluding 200V / 22kW and 400V / 30kW models).
- IM/PMSM common drive: Compatible with both induction motors and synchronous motors (PG interface card required for PMSM).
- Reduced torque ripple and minimized vibration during operation for enhanced ride comfort.
- Available in 200V and 400V models with motor capacities from 2.2 kW to 45 kW.
- Supports feedback from a wide range of pulse generators including Sin/Cos, EnDat2.1, Gray code, and UVM code.
- Long-life design: 7-year lifespan for capacitors, 5-year for cooling fan; includes life warning signals and cumulative run/operation data recording.
- Globally compliant with EN61800-5-1:2003 and EN954-1 Category 3 safety standards.
- Integrated RS-485 (Modbus RTU) and CAN Bus communication for efficient data exchange.
- Optional multi-function keypad with backlit LCD for easy programming and data copying/editing.
| Item | Specifications | |||||
|---|---|---|---|---|---|---|
| Type (FRN $\square$ LM1S-2) *10 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 |
| Nominal applied motor *1 [kVA] | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 |
| Rated capacity *2 [kVA] | 10.2 | 14 | 18 | 24 | 28 | |
| Rated voltage *3 [V] | Three-phase 200V-240V, 50/60Hz | |||||
| Rated current *4 [A] | 27.0 | 37.0 | 49.0 | 63.0 | 74.0 | |
| Overload capacity [A] (Permissible energizing time) | 54.0(10s) | 74.0(10s) | 98.0(10s) | 126.0(10s) | 148.0(10s) | |
| Overload capacity at carrier frequency 16kHz *15 [A] (Permissible energizing time) | 36(10s) | 49(10s) | 65(10s) | 84(10s) | 98(10s) | |
| Rated frequency [Hz] | 50, 60Hz | |||||
| Normal operation | ||||||
| Main power supply | Phases, Voltage, Frequency | Three-phase, 200 to 240V, 50/60Hz | ||||
| Auxiliary control power input | Single-phase, 200 to 240V, 50/60Hz | |||||
| Phases, Voltage, Frequency | Single-phase, 200 to 240V, 50/60Hz | |||||
| Voltage/frequency variations *8 | Voltage: +10 to -15% (Voltage unbalance: 2% or less *5) | |||||
| Frequency: +5 to -5% | ||||||
| Rated current *6 [A] | with DCR | 21.1 | 28.8 | 42.2 | 57.6 | 71.0 |
| without DCR | 31.5 | 42.7 | 60.7 | 80.1 | 97.0 | |
| Required power supply capacity *7 [kVA] | 7.4 | 10 | 15 | 20 | 25 | |
| Battery operation | ||||||
| Main power supply | Phases, Voltage, Frequency | DC 24V or more in the direct current voltage conversion. | ||||
| Auxiliary control power input *11 | Single-phase, 200 to 240V, 50/60Hz | |||||
| Voltage/frequency variations | Voltage: +10 to -15%, Frequency: +5 to -5% | |||||
| Operation time *12 [s] | 180 | |||||
| Braking time *13 [s] | 60 | |||||
| Braking duty-cycle (%ED) *13 [%] | 50 | |||||
| Rated regenerative power *13 [kW] | 4.4 | 6.0 | 8.8 | 12 | 14.8 | |
| Minimum resistance which can be connected [$\Omega$] *9 | 15 | 10 | 7.5 | 6 | 4 | |
| DC Reactor (DCR) | Option | |||||
| Applicable safety standard | EN61800-5-1 2003, EN954-1 Category3 *14 | |||||
| Enclosure (IEC60529) | IP20 | |||||
| Cooling method | Fan cooling | |||||
| Weight/Mass [kg] | 5.7 | 5.9 | 7.4 | 11.0 | 11.3 | 11.8 |
| Code | Name | Data setting range | Change when running | Data copying | Default | Drive control V/f |
Drive control PG V/f |
Drive control w/o PG |
Drive control w/ PG |
Torque Control |
|---|---|---|---|---|---|---|---|---|---|---|
| H03 | Data Initialization | 0 : Disable initialization 1 : Initialize all function code data to the factory defaults 2 : Initialize motor 1 parameters 3 : Initialize motor 2 parameters 4 : Initialize motor 3 parameters 5 : Initialize motor 4 parameters | N | N | 0 | Y | - | Y | Y | - |
| H04 | Auto-reset (Times Reset interval) | 0 : Disable; 1 to 10 | Y | Y | 0 | Y | - | Y | Y | - |
| H05 | Auto-reset (Times Reset interval) | 0.5 to 20.0 s | Y | Y | 5.0 | Y | - | Y | Y | - |
| H06 | Cooling Fan ON/OFF Control | 0 : Disable (Always in operation) 1 : Enable (ON/OFF controllable) | Y | Y | 0 | Y | - | Y | Y | - |
| H07 | Acceleration/Deceleration Pattern | 0 : Linear 1 : S-curve (Weak) 2 : S-curve (Arbitrary, according to H57 to H60 data) 3 : Curvilinear | Y | Y | 0 | Y | - | Y | Y | - |
| H08 | Rotational Direction Limitation | 0 : Disable 1 : Enable (Reverse rotation inhibited) 2 : Enable (Forward rotation inhibited) | N | Y | 0 | Y | - | Y | Y | - |
| H09 | Starting Mode (Auto search) | 0 : Disable 1 : Enable (At restart after momentary power failure) 2 : Enable (At restart after momentary power failure and at normal start) | N | Y | 0 | Y | - | N | N | - |
| H11 | Deceleration Mode | 0 : Normal deceleration 1 : Coast-to-stop | Y | Y | 0 | Y | - | Y | Y | - |
| H12 | Instantaneous Overcurrent Limiting (Mode selection) | 0 : Disable 1 : Enable | Y | Y | 1 | Y | - | Y | Y | - |
| H13 | Restart Mode after Momentary Power Failure (Restart time) (Frequency fall rate) (Continuous running level) (Allowable momentary power failure time) | 0.1 to 20.0 s | Y | Y1 Y2 | *10 | Y | - | Y | Y | - |
| H14 | 0.00: Deceleration time selected by F08, 0.01 to 100.00 Hz/s, 999: Follow the current limit command | Y | Y | 999 | Y | - | Y | N | - | |
| H15 | 200 to 300 V for 230 V series 400 to 600 V for 460 V series | Y | Y2 | 235/470 | Y | - | Y | N | - | |
| H16 | 0.0 to 30.0 s 999: Automatically determined by inverter | Y | Y | 999 | Y | - | Y | Y | - | |
| H18 | Torque Control Gain | 0 : Disable (Speed control) 2 : Enable (Torque current command) 3 : Enable (Torque command) | N | Y | 0 | N | - | Y | Y | - |
| H26 | Thermistor (for motor) (Mode selection) | 0 : Disable 1 : PTC (The inverter immediately trips with displayed.) 2 : PTC (The inverter issues output signal THM and continues to run.) 3 : NTC (When connected) | Y | Y | 0 | Y | - | Y | Y | - |
| H27 | 0.00 to 5.00 V | 0.00 to 5.00 V | Y | Y | 0.35 | Y | - | Y | Y | - |
| H28 | Droop Control | -60.0 to 0.0 Hz | Y | Y | 0 | Y | - | Y | Y | - |
| H30 | Communications Link Function (Mode selection) | Frequency command Run command 0 : F01/C30 F02 1 : RS-485 (Port 1) F02 2 : F01/C30 RS-485 (Port 1) 3 : RS-485 (Port 1) RS-485 (Port 1) 4 : RS-485 (Port 2) F02 5 : RS-485 (Port 2) RS-485 (Port 1) 6 : F01/C30 RS-485 (Port 2) 7 : RS-485 (Port 1) RS-485 (Port 2) 8 : RS-485 (Port 2) RS-485 (Port 2) | Y | Y | 0 | Y | - | Y | Y | - |
| H42 | Capacitance of DC Link Bus Capacitor | Indication for replacement of DC link bus capacitor 0 to 65535 | Y | N | - | Y | - | Y | Y | - |
| H43 | Cumulative Run Time of Cooling Fan | Indication for replacement of cooling fan 0 to 99990 hours | Y | N | - | Y | - | Y | Y | - |
| H44 | Startup Counter for Motor 1 | Indication of cumulative startup count 0 to 65535 times | Y | N | - | Y | - | Y | Y | - |
| H45 | Mock Alarm | 0 : Disable 1 : Enable (Once a mock alarm occurs, the data automatically returns to 0.) | Y | N | 0 | Y | - | Y | N | - |
| H46 | Starting Mode (Auto search delay time 2) | 0.1 to 20.0 s | Y | Y1 Y2 | *7 | Y | - | Y | N | - |
| H47 | Initial Capacitance of DC Link Bus Capacitor | Indication for replacement of DC link bus capacitor 0 to 65535 | Y | N | - | Y | - | Y | Y | - |
| H48 | Cumulative Run Time of Capacitors on Printed Circuit Boards | Indication for replacement of capacitors 0 to 99990 hours (The cumulative run time can be modified or reset.) | Y | N | - | Y | - | Y | Y | - |
| H49 | Starting Mode (Auto search delay time 1) | 0.0 to 10.0 s | Y | Y | 0.0 | Y | - | Y | Y | - |
| H50 | Non-linear V/f Pattern 1 (Frequency) (Voltage) | 0.0: Cancel, 0.1 to 500.0 Hz | N | Y | 0.0 | Y | - | N | N | - |
| H51 | 0 to 240 : Output an AVR-controlled voltage (for 230 V series) 0 to 500 : Output an AVR-controlled voltage (for 460 V series) | N | Y2 | 0 | Y | - | N | N | - | |
| H52 | Non-linear V/f Pattern 2 (Frequency) (Voltage) | 0.0: Cancel, 0.1 to 500.0 Hz | N | Y | 0.0 | Y | - | N | N | - |
| H53 | 0 to 240 : Output an AVR-controlled voltage (for 230 V series) 0 to 500 : Output an AVR-controlled voltage (for 460 V series) | N | Y2 | 0 | Y | - | N | N | - | |
| H54 | Acceleration Time (Jogging) | 0.00 to 6000 s | Y | Y | *1 | Y | - | Y | Y | - |
| H55 | Deceleration Time (Jogging) | 0.00 to 6000 s | Y | Y | *1 | Y | - | Y | Y | - |
| H56 | Deceleration Time for Forced Stop | 0.00 to 6000 s | Y | Y | *1 | Y | - | Y | Y | - |
| H57 | 1st S-curve acceleration range (Leading edge) | 0% to 100% | Y | Y | *10 | Y | - | Y | Y | - |
| H58 | 2nd S-curve acceleration range (Trailing edge | 0% to 100% | Y | Y | 10 | Y | - | Y | Y | - |
| H59 | 1st S-curve deceleration range (Leading edge) | 0% to 100% | Y | Y | 10 | Y | - | Y | Y | - |
| H60 | 2nd S-curve deceleration range (Trailing edge | 0% to 100% | Y | Y | 10 | Y | - | Y | Y | - |
| H61 | UP/DOWN Control (Initial frequency setting) | 0 :0.00 Hz 1 : Last UP/DOWN command value on releasing the run command | N | Y | 1 | Y | - | Y | Y | - |
| H63 | Low Limiter (Mode selection) (Lower limiting frequency) | 0 : Limit by F16 (Frequency limiter: Low) and continue to run 1 : If the output frequency lowers below the one limited by F16 (Frequency limiter: Low), decelerate to stop the motor. | Y | Y | 1 | Y | - | Y | Y | - |
| H64 | (Lower limiting frequency) | 0.0: Depends on F16 (Frequency limiter, Low) 0.1 to 60.0 Hz | Y | Y | 1.6 | Y | - | N | N | - |
| H65 | Non-linear V/f Pattern 3 (Frequency) (Voltage) | 0.0: Cancel, 0.1 to 500.0 Hz | N | Y | 0.0 | Y | - | N | N | - |
| H66 | 0 to 240 :Output an AVR-controlled voltage (for 230 V series) 0 to 500 :Output an AVR-controlled voltage (for 460 V series) | N | Y2 | 0 | Y | - | N | N | - | |
| H67 | Auto Energy Saving Operation (Mode selection) | 0 : Enable during running at constant speed 1 : Enable in all modes | Y | Y | 0 | Y | - | N | Y | - |
|
Catalog Name
|
Catalog Number[size]
|
Last Update
|
|---|---|---|
| FRENIC-Lift Catalog (available on request) | [3400KB] | Aug. 2017 |
Applications
- Passenger elevators in residential and commercial buildings
- Freight and service elevators requiring precise control
- Hospital elevators needing smooth, low-vibration operation
- Machine-room-less (MRL) elevator systems
- Elevator systems requiring regeneration and braking capabilities
- Elevators using synchronous (PMSM) or induction motors
- High-rise buildings requiring advanced torque and speed control
- Elevator modernization projects requiring compatibility with various encoders and control systems
- Lift systems with demand for reduced roll-back during start-up
- Applications needing long-life and low-maintenance drive systems
Why Choose
- Affordability: Low-cost control without compromising quality.
- Flexibility: Expandable I/O and communication options.
- Reliability: Built on Omron's decades-long industrial automation expertise.
- Ease of Use: Intuitive software and compact design simplify deployment.