Omron S8VS Series SMPS Indicator
The Omron S8VS is a compact and intelligent single-phase SMPS designed for enhanced reliability and status visibility. With built-in digital indicators, the S8VS series makes it easy to monitor output voltage, run time, and maintenance alarms—ideal for preventive maintenance in control panels.
Categories:
Panel ComponentsKey Features
- Status displayed on 3-digit, 7-segment display. *
- Signal output notifications at 90 W or more. *
- Conformity to various safety standards for global usability.
- Varied coverage with 3-year warranty.
- DIN rail mounting supported.
| Power ratings | 15 W | 30 W | ||||||
|---|---|---|---|---|---|---|---|---|
| Output voltage (VDC) | 5 V | 12 V | 24 V | 5 V | 12 V | 24 V | ||
| Efficiency | With 100-VAC input | 74% typical | 79% typical | 83% typical | 74% typical | 81% typical | 85% typical | |
| With 200-VAC input | 73% typical | 78% typical | 80% typical | 74% typical | 80% typical | 86% typical | ||
| Input | Voltage *1 | 100 to 240 VAC (allowable range: 85 to 264 VAC, 80 to 370 VDC *5) | ||||||
| Frequency *1 | 50/60 Hz (47 to 450 Hz) | |||||||
| Current | With 100-VAC input | 0.45 A max., 0.34 A typical | 0.9 A max., 0.66 A typical | |||||
| With 200-VAC input | 0.25 A max., 0.22 A typical | 0.6 A max., 0.4 A typical | ||||||
| Power factor *6 | --- | |||||||
| Harmonic current regulation | Conforms to EN61000-3-2 | |||||||
| Leakage
current |
With 100-VAC input | 0.5 mA max. | ||||||
| With 200-VAC input | 1.0 mA max. | |||||||
| Inrush
current *2 |
With 100-VAC input | 17.5 A max., 14 A typical | ||||||
| With 200-VAC input | 35 A max., 28 A typical | |||||||
| Output | Voltage adjustment range *3 | - 10% to 15% (with V.ADJ) | ||||||
| Ripple noise voltage (at rated I/O) | 60 mV max. | 70 mV max. | 60 mV max. | 60 mV max. | 90 mV max. | 150 mV max. | ||
| Input variation influence | 0.5% max. (at 85- to 264-VAC input, 100% load) | |||||||
| Load variation influence
(rated input voltage) |
2.0% max. (5 V), 1.5% max. (12 V, 24 V), (with rated input, 0 to 100% load) | |||||||
| Temperature variation influence | 0.05%/°C max. | |||||||
| Startup time
(at rated I/O) *2 |
With 100-VAC input | 580 ms typical | 530 ms typical | 600 ms typical | 500 ms typical | 560 ms typical | 560 ms typical | |
| With 200-VAC input | 340 ms typical | 360 ms typical | 400 ms typical | 360 ms typical | 380 ms typical | 400 ms typical | ||
| Output hold time
(at rated I/O) *2 |
With 100-VAC input | 39 ms typical | 27 ms typical | 28 ms typical | 31 ms typical | 22 ms typical | 31 ms typical | |
| With 200-VAC input | 187 ms typical | 134 ms typical | 134 ms typical | 174 ms typical | 123 ms typical | 140 ms typical | ||
| Additional
functions |
Overload protection *2 | The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC). | ||||||
| Overvoltage protection *2 | Yes *4 | |||||||
| Output voltage indication | No | |||||||
| Output current indication | No | |||||||
| Peak-hold current indication | No | |||||||
| Maintenance forecast monitor indication | No | |||||||
| Maintenance forecast monitor output | No | |||||||
| Total run time monitor indication | No | |||||||
| Total run time monitor output | No | |||||||
| Undervoltage alarm indication | Yes (color: red) | |||||||
| Undervoltage alarm output | No | |||||||
| Parallel operation | No (However, backup operation is possible. An external diode is required.) | |||||||
| Series operation | Models with 24-V output: Possible for up to 2 Power Supplies (with external diode)
Models with 5- or 12-V output: Not possible |
|||||||
| Other | Operating ambient temperature | Refer to the derating curve in Engineering Data. (with no icing or condensation) | ||||||
| Storage temperature | - 25 to 65°C | |||||||
| Operating ambient humidity | 25% to 85% (Storage humidity: 25% to 90%) | |||||||
| Dielectric strength | 3.0 kVAC for 1 min. (between all inputs and outputs; detection current: 20 mA)
2.0 kVAC for 1 min. (between all inputs and PE terminals; detection current: 20 mA) 1.0 kVAC for 1 min. (between all outputs and PE terminals; detection current: 20 mA) |
|||||||
| Insulation resistance | 100 MΩ min. (between all outputs and all inputs/PE terminals) at 500 VDC | |||||||
| Vibration resistance | 10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions | |||||||
| Shock resistance | 150 m/s2 , 3 times each in ±X, ±Y, and ±Z directions | |||||||
| Output indicator | Yes (color: green) | |||||||
| EMI | Conducted Emissions | Conforms to EN55011 Group1 Class B and based on FCC Class A | ||||||
| Radiated Emissions | Conforms to EN55011 Group1 Class B | |||||||
| EMS | Conforms to EN61204-3 high severity levels | |||||||
| Approved standards | UL 508 (Listing, Class2 Output: Per 1310)
UL 62368-1 CSA C22.2 No.107.1 (cUL) (Class2 Output: Per CSA C22.2 No.223) CSA C22.2 No.62368-1 (cUR) EN 62477-1, EN 62368-1 RCM mark BIS: IS 13252 (Part 1) (30 W, 12 V and 24 V only) *7 |
|||||||
| SEMI | F47-0706 (With 200-VAC input) | |||||||
| Weight | 160 g max. | 180 g max. | ||||||
| Power ratings | 60 W | ||||
|---|---|---|---|---|---|
| Type | Standard | Maintenance forecast
monitor |
Total run time
monitor |
||
| Efficiency | With 100-VAC input | 84% typical | 83% typical | ||
| With 200-VAC input | 83% typical | 85% typical | |||
| Input | Voltage *1 | 100 to 240 VAC (allowable range: 85 to 264 VAC or 80 to 370 VDC *11) | |||
| Frequency *1 | 50/60 Hz (47 to 450 Hz) | ||||
| Current | With 100-VAC input | 1.7 A max., 1.3 A typical | 1.7 A max., 1.3 A typical | ||
| With 200-VAC input | 1.0 A max., 0.68 A typical | 1.0 A max., 0.78 A typical | |||
| Power factor *12 | --- | ||||
| Harmonic current regulation | Conforms to EN61000-3-2 | ||||
| Leakage current | With 100-VAC input | 0.5 mA max. | |||
| With 200-VAC input | 1.0 mA max. | ||||
| Inrush current *2 | With 100-VAC input | 17.5 A max., 14 A typical | |||
| With 200-VAC input | 35 A max., 28 A typical | ||||
| Output | Voltage adjustment range *3 | -10% to 15% (with V. ADJ) (The voltage cannot be adjusted for the S8VS-09024[][][]S-[].) | |||
| Ripple noise voltage (at rated I/O) | 70 mV max. | 90 mV max. | |||
| Input variation influence | 0.5% max. (at 85- to 264-VAC input, 100% load) | ||||
| Load variation influence (rated input voltage) | 1.5% max. (with rated input, 0 to 100% load) | ||||
| Temperature variation influence | 0.05%/°C max. | ||||
| Startup time
(at rated I/O) *2 |
With 100-VAC input | 620 ms typical | 460 ms typical | ||
| With 200-VAC input | 400 ms typical | 290 ms typical | |||
| Output hold time
(at rated I/O) *2 |
With 100-VAC input | 34 ms typical | 33 ms typical | ||
| With 200-VAC input | 158 ms typical | 154 ms typical | |||
| Additional
functions |
Overload protection *2 | 105% to 160% of rated load current (101% to 110% of rated load current for the S8VS-09024[][][]S-[]),
inverted L voltage drop, intermittent, automatic reset |
|||
| Overvoltage protection *2, *4 | Yes | ||||
| Output voltage indication *5 | No | Yes (selectable) *6 | |||
| Output current indication *5 | No | Yes (selectable) *7 | |||
| Peak-hold current indication *5 | No | Yes (selectable) *8 | |||
| Maintenance forecast monitor indication *5 | No | Yes (selectable) | No | ||
| Maintenance forecast monitor output | No | ||||
| Total run time monitor indication *5 | No | Yes (selectable) | |||
| Total run time monitor output *5 | No | ||||
| Undervoltage alarm indication *5 | No | Yes (selectable) | |||
| Undervoltage alarm output terminals | No | ||||
| Parallel operation | No (However, backup operation is possible. An external diode is required.) | ||||
| Series operation | Yes for up to 2 Power Supplies (with external diode) | ||||
| Other | Operating ambient temperature | Refer to the derating curve in . (with no icing or condensation) | |||
| Storage temperature | -25 to 65°C | ||||
| Operating ambient humidity | 25% to 85% (Storage humidity: 25% to 90%) | ||||
| Dielectric strength | 3.0 kVAC for 1 min. (between all inputs and outputs/ alarm outputs; detection current: 20 mA)
2.0 kVAC for 1 min. (between all inputs and PE terminals; detection current: 20 mA) 1.0 kVAC for 1 min. (between all outputs/ alarm outputs and PE terminals; detection current for standard models: 30 mA, detection current for models with indication monitor: 20 mA) 500 VAC for 1 min. (between all outputs and alarm outputs; detection current: 20 mA) |
||||
| Insulation resistance | 100 MΩ min. (between all outputs/ alarm outputs and all inputs/ PE terminals) at 500 VDC | ||||
| Vibration resistance | 10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions
10 to 150 Hz, 0.35-mm single amplitude (5 G max.) for 80 min each in X, Y, and Z directions |
||||
| Shock resistance | 150 m/s2, 3 times each in ±X, ±Y, and ±Z directions | ||||
| Output indicator | Yes (color: green) | ||||
| EMI | Conducted
Emissions |
Models with indication monitor: Conforms to EN55011 Group1 Class A and based on FCC Class A,
Conforms to EN55011 Group1 Class B *11 Standard models: Conforms to EN61204-3 EN55011 Group 1 Class B and based on FCC Class A |
|||
| Radiated
Emissions |
Models with indication monitor: Conforms to EN55011 Group1 Class A, Conforms to EN55011 Group1 Class B *11
Standard models: Conforms to EN55011 Group1 Class B |
||||
| EMS | Conforms to EN61204-3 high severity levels | ||||
| Approved standards *11 | Standard model:
UL 508 (Listing; Class 2 Output: Per UL1310) UL 62368-1 CSA C22.2 No.107.1 (cUL) (Class 2 Output: Per CSA C22.2 No. 223) CSA C22.2 No.62368-1 (cUR) EN 62477-1, EN 62368-1 RCM mark With indication monitor: UL 508 (Listing, Class2 Output: Per 1310) CSA C22.2 No.107.1 (cUL) (Class2 Output: Per CSA C22.2 No.223) EN 62477-1 RCM mark, KOSHA S Mark *10 BIS: IS 13252 (Part 1) *13 |
||||
| SEMI *11 | F47-0706 (With 200-VAC input) | ||||
| Weight | 330 g max. | ||||
| Power ratings | Input voltage | Output voltage (VDC) | Output current | UL Class 2 Output standards | Model number (screw terminal block) | Model number (screwless terminal block) |
|---|---|---|---|---|---|---|
| 15 W | 100 to 240 VAC (allowable range: 85 to 264 VAC or 80 to 370 VDC *3) | 5 V | 2.0 A | Yes | S8VS-01505 *1 | --- |
| 12 V | 1.2 A | Yes | S8VS-01512 | |||
| 24 V | 0.65 A | Yes | S8VS-01524 | |||
| 30 W | 5 V | 4.0 A | Yes | S8VS-03005 *2 | ||
| 12 V | 2.5 A | Yes | S8VS-03012 | |||
| 24 V | 1.3 A | Yes | S8VS-03024 | |||
| 60 W | 24 V | 2.5 A | Yes | S8VS-06024 | S8VS-06024-F | |
| 90 W | 24 V | 3.75 A | --- | S8VS-09024 | S8VS-09024-F | |
| Yes | S8VS-09024S | S8VS-09024S-F | ||||
| 120 W | 24 V | 5 A | --- | S8VS-12024 | S8VS-12024-F | |
| 180 W | 24 V | 7.5 A | --- | S8VS-18024 | S8VS-18024-F | |
| 240 W | 24 V | 10 A | --- | S8VS-24024 | S8VS-24024-F | |
| 480 W | 100 to 240 VAC | 20 A (Peak current 30 A) | --- | S8VS-48024 | S8VS-48024-F |
|
Catalog Name
|
Catalog Number[size]
|
Last Update
|
|---|---|---|
| S8VS Data Sheet | T026-E1-16 [5815KB] |
Jul 08, 2024 |
Applications
- Control panels with maintenance plans
- Automation systems
- Sensor/PLC/relay power supply
- Process and packaging machinery
- Semiconductor tools (SEMI F47)