Omron S8VK-S Series SMPS Indicator
The S8VK-S is Omron’s slim-design, single-phase power supply, built to save space in control panels while maintaining reliable performance in industrial environments. It’s part of the renowned S8VK family known for stability, durability, and easy installation.
Categories:
Panel ComponentsKey Features
-
Ultra-Slim Design:
- Perfect for space-limited control panels
- Width as narrow as 22.5 mm
-
Global Input Range:
- Input voltage: 85–264 VAC or 90–350 VDC
- Compatible with international standards
-
Output Voltages:
- Available in 5V, 12V, 15V, 24V, and 48V DC
- Precise voltage regulation and stability
-
Operating Temperature:
- Wide range from –25°C to +60°C
- Fanless design ensures low maintenance
-
Easy DIN Rail Mounting:
- Tool-free clip-in installation
- Quick wiring with front terminals
-
Built-in Protection:
- Overload, overvoltage, and short-circuit protection
- Output status LED indicator
-
Certifications:
- UL, cULus, CE, EN, and more
| Power rating | 30 W | 60 W | 120 W | ||
|---|---|---|---|---|---|
| Output voltagec (DC) | 24 V | 24 V | 24 V | ||
| Efficiency | 115 VAC input *1 | 87% typ. | 87% typ. | 90% typ. | |
| 230 VAC input *1 | 86% typ. | 89% typ. | 92% typ. | ||
| Input | Voltage range *2 | Single-phase, 85 to 264 VAC, 90 to 350 VDC *12,
265 to 300 VAC (1 second) |
|||
| Frequency *2 | 50/60 Hz (47 to 450 Hz) | 50/60 Hz (47 to 63
Hz) |
|||
| Input current | 115 VAC input *1 | 0.58A typ. | 1.1 A typ. | 1.2 A typ. | |
| 230 VAC input *1 | 0.36A typ. | 0.66 A typ. | 0.63 A typ. | ||
| Power factor *1 | --- | 0.9 min. | |||
| Leakage
current *3 |
115 VAC input | 0.5 mA max. | |||
| 230 VAC input | 1 mA max. | ||||
| Inrush current
*4 (for a cold start at 25°C) |
115 VAC input | 16 A typ. | |||
| 230 VAC input | 32 A typ. | ||||
| Output | Rated output current | 1.3 A | 2.5 A | 5 A | |
| Rated output electric power | 31.2 W | 60 W | 120 W | ||
| Maximum boost current | 1.56 A | 3 A | 6 A | ||
| Voltage adjustment range *5 | 21.6 to 28 V (with V.DJ) | ||||
| Ripple & Noise
voltage *6 |
100 to 240 VAC
input *1 |
190 mVp-p max. at
20 MHz of bandwidth |
190 mVp-p max. at
20 MHz of bandwidth |
110 mVp-p max. at
20 MHz of bandwidth |
|
| Input variation influence *7 | 0.5% max. | ||||
| Load variation influence *8 | 1.5% max. | ||||
| Temperature
variation influence |
115 to 230 VAC
input |
0.05%/°C max. | |||
| Start up time
*4 |
115 VAC input *1 | 1000 ms max. | 1000 ms max. | 1000 ms max. | |
| 230 VAC input *1 | 1000 ms max. | 1000 ms max. | 1000 ms max. | ||
| Hold time *6 | 115 VAC input *1 | 30 ms typ. | 20 ms typ. | 45 ms typ. | |
| 230 VAC input *1 | 140 ms typ. | 95 ms typ. | 45 ms typ. | ||
| Additional
functions |
Overload protection | Yes, automatic reset | |||
| Overvoltage protection *9 | Yes, 130% or higher of rated output voltage, power shut off (shut
off the input voltage and turn on the input again) |
||||
| Series operation | Yes (For up to two Power Supplies, external diodes are required.) | ||||
| Parallel operation | Yes (For up to two Power Supplies), Refer to Parallel Operation on
catalog for details. |
||||
| Output indicator | Yes (LED: Green) | ||||
| Low-voltage detection output | No | ||||
| Insulation | Withstand voltage | 3.0 kVAC for 1 min. (between all input terminals and output
terminals), current cutoff 10 mA |
|||
| 2.0 kVAC for 1 min. (between all input terminals and PE terminals),
current cutoff 10 mA |
|||||
| 1.0 kVAC for 1 min. (between all output terminals and PE terminals),
current cutoff 20 mA |
|||||
| Insulation resistance | 100 MΩ min. (between all output terminals and all input terminals/
PE terminals) at 500 VDC |
||||
| Environ-
ment |
Ambient operating temperature
*10 |
-40 to 70°C (Derating is required according to the temperature.
Refer to Engineering Data) (with no condensation or icing) |
|||
| Storage temperature | -40 to 85°C (with no condensation or icing) | ||||
| Ambient operating humidity | 95% RH max. (Storage humidity: 95% RH max.) | ||||
| Vibration resistance | 10 to 55 Hz, maximum 5G, 0.42 mm half amplitude for 2 h each in
X, Y, and Z directions |
||||
| Shock resistance | 150 m/s2, 3 times each in ±X, ±Y, ±Z directions | ||||
| Reliability | MTBF | 135,000 hrs min. (Refer to Data Sheet Reference Value) | |||
| Life expectancy *11 | 10 years min. | ||||
| Con-
struction |
Weight | 250 g max. | 250 g max. | 400 g max. | |
| Cooling fan | No | ||||
| Degree of protection | IP20 by EN/IEC 60529 | ||||
| Standards | Harmonic current emissions | Conforms to EN 61000-3-2 | |||
| EMI | Conducted
Emissions |
Conforms to EN 61204-3 Class B, EN 55011 Class B | |||
| Radiated
Emissions |
Conforms to EN 61204-3 Class B, EN 55011 Class B | ||||
| EMS | Conforms to EN 61204-3 high severity levels | ||||
| Safety standards | UL Listing: UL 508 (For 30 W and 60 W only Class2 Output: Per UL 1310)
cUL: CSA C22.2 No107.1 (For 30 W and 60 W only Class2 Output: Per CSA C22.2 No.223) UL UR: UL 62368-1 (Recognition) OVCII (≤ 3000 m) Pol2 cUR: CSA C22.2 No. 62368-1 OVCII (≤ 3000 m) Pol2 EN: EN 62477-1 OVCIII (≤ 2000 m) OVCII (2000 m≤ and≤3000) Pol2, EN 62368-1 OVCII (≤ 3000 m) Pol2 RCM (EN61000-6-4) PELV (EN/IEC 60204-1) *12 EN/IEC 61558-2-16:2009+A1:2013 *12 BIS: IS 13252 (Part1) (Except 30 W) *12 |
||||
| Marine Standards *12 | Lloyd’s register (Except 30 W) | ||||
| SEMI | Conforms to F47-0706 (200 to 240 VAC input) | ||||
| Power rating | 240 W | 480 W | ||
|---|---|---|---|---|
| Output voltagec (DC) | 24 V | 24 V | ||
| Efficiency | 115 VAC input *1 | 91% typ. | 91% typ. | |
| 230 VAC input *1 | 93% typ. | 93% typ. | ||
| Input | Voltage range *2 | Single-phase, 85 to 264 VAC, 90 to 350 VDC *12, 265 to 300 VAC
(1 second) |
||
| Frequency *2 | 50/60 Hz (47 to 63 Hz) | |||
| Input current | 115 VAC input *1 | 2.4 A typ. | 4.6 A typ. | |
| 230 VAC input *1 | 1.3 A typ. | 2.3 A typ. | ||
| Power factor *1 | 0.9 min. | 0.9 min. | ||
| Leakage
current *3 |
115 VAC input | 0.5 mA max. | ||
| 230 VAC input | 1 mA max. | |||
| Inrush current
*4 (for a cold start at 25°C) |
115 VAC input | 16 A typ. | ||
| 230 VAC input | 32 A typ. | |||
| Output | Rated output current | 10 A | 20 A | |
| Rated output electric power | 240 W | 480 W | ||
| Maximum boost current | 15 A | 30 A | ||
| Voltage adjustment range *5 | 21.6 to 28 V (with V.ADJ) | |||
| Ripple & Noise
voltage *6 |
100 to 240 VAC
input *1 |
100 mVp-p max.
at 20 MHz of bandwidth |
130 mVp-p max.
at 20 MHz of bandwidth |
|
| Input variation influence *7 | 0.5% max. | |||
| Load variation influence *8 | 1.5% max. | |||
| Temperature
variation influence |
115 to 230 VAC
input |
0.05%/°C max. | ||
| Start up time
*4 |
115 VAC input *1 | 1000 ms max. | 1000 ms max. | |
| 230 VAC input *1 | 1000 ms max. | 1000 ms max. | ||
| Hold time *6 | 115 VAC input *1 | 35 ms typ. | 30 ms typ. | |
| 230 VAC input *1 | 35 ms typ. | 30 ms typ. | ||
| Additional
functions |
Overload protection | Yes, automatic reset | ||
| Overvoltage protection *9 | Yes, 130% or higher of rated output voltage, power shut off (shut
off the input voltage and turn on the input again) |
|||
| Series operation | Yes (For up to two Power Supplies, external diodes are required.) | |||
| Parallel operation | Yes (For up to two Power Supplies), Refer to Parallel Operation on
catalog for details. |
|||
| Output indicator | Yes (LED: Green) | |||
| Low-voltage detection output | Yes (Photoswitch output: 30 VDC max., 50 mA max.) | |||
| Insulation | Withstand voltage | 3.0 kVAC for 1 min. (between all input terminals and output
terminals), current cutoff 20 mA |
||
| 2.0 kVAC for 1 min. (between all input terminals and PE terminals),
current cutoff 20 mA |
||||
| 1.0 kVAC for 1 min. (between all output terminals and PE terminals),
current cutoff 20 mA |
||||
| 500 VAC for 1 min (between all output terminals and all low-voltage
detection output terminals), current cutoff 10 mA |
||||
| Insulation resistance | 100 MΩ min. (between all output terminals/all low-voltage
detection output terminals and all input terminals/PE terminals) at 500 VDC |
|||
| Environ-
ment |
Ambient operating temperature
*10 |
-40 to 70°C (Derating is required according to the temperature.
Refer to Engineering Data) (with no condensation or icing) |
||
| Storage temperature | -40 to 85°C (with no condensation or icing) | |||
| Ambient operating humidity | 95% RH max. (Storage humidity: 95% RH max.) | |||
| Vibration resistance | 10 to 55 Hz, maximum 5G, 0.42 mm half amplitude for 2 h each in
X, Y, and Z directions |
|||
| Shock resistance | 150 m/s2, 3 times each in ±X, ±Y, ±Z directions | |||
| Reliability | MTBF | 135,000 hrs min. (Refer to Data Sheet Reference Value) | ||
| Life expectancy *11 | 10 years min. | |||
| Con-
struction |
Weight | 700 g max. | 1150 g max. | |
| Cooling fan | No | |||
| Degree of protection | IP20 by EN/IEC 60529 | |||
| Standards | Harmonic current emissions | Conforms to EN 61000-3-2 | ||
| EMI | Conducted
Emissions |
Conforms to EN 61204-3 Class B, EN 55011 Class B | ||
| Radiated
Emissions |
Conforms to EN 61204-3 Class B, EN 55011 Class B | |||
| EMS | Conforms to EN 61204-3 high severity levels | |||
| Safety standards | UL Listing: UL 508
cUL: CSA C22.2 No107.1 UL UR: UL 62368-1 (Recognition) OVCII (≤ 3000 m) Pol2 cUR: CSA C22.2 No.62368-1 OVCII (≤ 3000 m) Pol2 EN: EN 62477-1 OVCIII (≤ 2000 m) OVCII (2000 m≤ and≤3000) Pol2, EN 62368-1 OVCII (≤ 3000 m) Pol2 PELV (EN/IEC 60204-1) *12 EN/IEC 61558-2-16:2009+A1:2013 *12 BIS: IS 13252 (Part1) *12 |
|||
| Marine Standards *12 | Lloyd's register | |||
| SEMI | Conforms to F47-0706 (200 to 240 VAC input) | |||
| Power ratings | Rated input voltage | Rated output voltage (DC) | Rated output current | Maximum boost current | Model number |
|---|---|---|---|---|---|
| 30 W | 100 to 240 (VAC allowable range: 85 to 264 VAC or 90 to 350 VDC) | 24 V | 1.3 A | 1.56 A | S8VK-S03024 |
| 60 W | 24 V | 2.5 A | 3 A | S8VK-S06024 | |
| 120 W | 24 V | 5 A | 6 A | S8VK-S12024 | |
| 240 W | 24 V | 10 A | 15 A | S8VK-S24024 | |
| 480 W | 24 V | 20 A | 30 A | S8VK-S48024 |
|
Catalog Name
|
Catalog Number[size]
|
Last Update
|
|---|---|---|
| S8VK-S Data Sheet | T205-E1-14 [5868KB] |
Jul 08, 2024 |
| S8VK-W/S8VK-S Catalog | T235-E1-05 [2061KB] |
Nov 18, 2024 |
| S8VK-S/S8FS-G Power Supply Guide Catalog | T209-E1-09 [2280KB] |
Oct 23, 2023 |
| XW6T Catalog | G139-E1-06 [4370KB] |
Nov 13, 2023 |
| Value Design for Panel Catalog | Y235-E1-07 [5229KB] |
May 19, 2025 |
Applications
- Compact control panels
- Sensor and controller power supply
- Building automation
- Packaging machines
- Small machinery and conveyors
Why Choose
- Slim body = More space in control cabinets
- Global input voltage compatibility
- Simple DIN rail installation
- Excellent cost-performance ratio
- Robust, fanless design for reliability
Inquiry Now
Brands