Founded in 2012, Shree Vijayvargiya Technologies Pvt. Ltd. is a leading provider of industrial and commercial supplies, specializing in industrial switchgear and automation products. We focus on excellence, innovation, and customer delight across wholesale, distribution, and automation solutions.

Our Socials

Omron S8VK-S SMPS Indicator

Omron S8VK-S Series SMPS Indicator

The S8VK-S is Omron’s slim-design, single-phase power supply, built to save space in control panels while maintaining reliable performance in industrial environments. It’s part of the renowned S8VK family known for stability, durability, and easy installation.

Categories:

Panel Components

Key Features

  • Ultra-Slim Design:
    • Perfect for space-limited control panels
    • Width as narrow as 22.5 mm
  • Global Input Range:
    • Input voltage: 85–264 VAC or 90–350 VDC
    • Compatible with international standards
  • Output Voltages:
    • Available in 5V, 12V, 15V, 24V, and 48V DC
    • Precise voltage regulation and stability
  • Operating Temperature:
    • Wide range from –25°C to +60°C
    • Fanless design ensures low maintenance
  • Easy DIN Rail Mounting:
    • Tool-free clip-in installation
    • Quick wiring with front terminals
  • Built-in Protection:
    • Overload, overvoltage, and short-circuit protection
    • Output status LED indicator
  • Certifications:
    • UL, cULus, CE, EN, and more
Power rating 30 W 60 W 120 W
Output voltagec (DC) 24 V 24 V 24 V
Efficiency 115 VAC input *1 87% typ. 87% typ. 90% typ.
230 VAC input *1 86% typ. 89% typ. 92% typ.
Input Voltage range *2 Single-phase, 85 to 264 VAC, 90 to 350 VDC *12,
265 to 300 VAC (1 second)
Frequency *2 50/60 Hz (47 to 450 Hz) 50/60 Hz (47 to 63
Hz)
Input current 115 VAC input *1 0.58A typ. 1.1 A typ. 1.2 A typ.
230 VAC input *1 0.36A typ. 0.66 A typ. 0.63 A typ.
Power factor *1 --- 0.9 min.
Leakage
current *3
115 VAC input 0.5 mA max.
230 VAC input 1 mA max.
Inrush current
*4 (for a cold
start at 25°C)
115 VAC input 16 A typ.
230 VAC input 32 A typ.
Output Rated output current 1.3 A 2.5 A 5 A
Rated output electric power 31.2 W 60 W 120 W
Maximum boost current 1.56 A 3 A 6 A
Voltage adjustment range *5 21.6 to 28 V (with V.DJ)
Ripple & Noise
voltage *6
100 to 240 VAC
input *1
190 mVp-p max. at
20 MHz of bandwidth
190 mVp-p max. at
20 MHz of bandwidth
110 mVp-p max. at
20 MHz of bandwidth
Input variation influence *7 0.5% max.
Load variation influence *8 1.5% max.
Temperature
variation
influence
115 to 230 VAC
input
0.05%/°C max.
Start up time
*4
115 VAC input *1 1000 ms max. 1000 ms max. 1000 ms max.
230 VAC input *1 1000 ms max. 1000 ms max. 1000 ms max.
Hold time *6 115 VAC input *1 30 ms typ. 20 ms typ. 45 ms typ.
230 VAC input *1 140 ms typ. 95 ms typ. 45 ms typ.
Additional
functions
Overload protection Yes, automatic reset
Overvoltage protection *9 Yes, 130% or higher of rated output voltage, power shut off (shut
off the input voltage and turn on the input again)
Series operation Yes (For up to two Power Supplies, external diodes are required.)
Parallel operation Yes (For up to two Power Supplies), Refer to Parallel Operation on
catalog for details.
Output indicator Yes (LED: Green)
Low-voltage detection output No
Insulation Withstand voltage 3.0 kVAC for 1 min. (between all input terminals and output
terminals), current cutoff 10 mA
2.0 kVAC for 1 min. (between all input terminals and PE terminals),
current cutoff 10 mA
1.0 kVAC for 1 min. (between all output terminals and PE terminals),
current cutoff 20 mA
Insulation resistance 100 MΩ min. (between all output terminals and all input terminals/
PE terminals) at 500 VDC
Environ-
ment
Ambient operating temperature
*10
-40 to 70°C (Derating is required according to the temperature.
Refer to Engineering Data) (with no condensation or icing)
Storage temperature -40 to 85°C (with no condensation or icing)
Ambient operating humidity 95% RH max. (Storage humidity: 95% RH max.)
Vibration resistance 10 to 55 Hz, maximum 5G, 0.42 mm half amplitude for 2 h each in
X, Y, and Z directions
Shock resistance 150 m/s2, 3 times each in ±X, ±Y, ±Z directions
Reliability MTBF 135,000 hrs min. (Refer to Data Sheet Reference Value)
Life expectancy *11 10 years min.
Con-
struction
Weight 250 g max. 250 g max. 400 g max.
Cooling fan No
Degree of protection IP20 by EN/IEC 60529
Standards Harmonic current emissions Conforms to EN 61000-3-2
EMI Conducted
Emissions
Conforms to EN 61204-3 Class B, EN 55011 Class B
Radiated
Emissions
Conforms to EN 61204-3 Class B, EN 55011 Class B
EMS Conforms to EN 61204-3 high severity levels
Safety standards UL Listing: UL 508 (For 30 W and 60 W only Class2 Output: Per UL 1310)
cUL: CSA C22.2 No107.1 (For 30 W and 60 W only Class2 Output: Per CSA C22.2 No.223)
UL UR: UL 62368-1 (Recognition) OVCII (≤ 3000 m) Pol2
cUR: CSA C22.2 No. 62368-1 OVCII (≤ 3000 m) Pol2
EN: EN 62477-1 OVCIII (≤ 2000 m) OVCII (2000 m≤ and≤3000) Pol2,
EN 62368-1 OVCII (≤ 3000 m) Pol2
RCM (EN61000-6-4)
PELV (EN/IEC 60204-1) *12
EN/IEC 61558-2-16:2009+A1:2013 *12
BIS: IS 13252 (Part1) (Except 30 W) *12
Marine Standards *12 Lloyd’s register (Except 30 W)
SEMI Conforms to F47-0706 (200 to 240 VAC input)
Power rating 240 W 480 W
Output voltagec (DC) 24 V 24 V
Efficiency 115 VAC input *1 91% typ. 91% typ.
230 VAC input *1 93% typ. 93% typ.
Input Voltage range *2 Single-phase, 85 to 264 VAC, 90 to 350 VDC *12, 265 to 300 VAC
(1 second)
Frequency *2 50/60 Hz (47 to 63 Hz)
Input current 115 VAC input *1 2.4 A typ. 4.6 A typ.
230 VAC input *1 1.3 A typ. 2.3 A typ.
Power factor *1 0.9 min. 0.9 min.
Leakage
current *3
115 VAC input 0.5 mA max.
230 VAC input 1 mA max.
Inrush current
*4 (for a cold
start at 25°C)
115 VAC input 16 A typ.
230 VAC input 32 A typ.
Output Rated output current 10 A 20 A
Rated output electric power 240 W 480 W
Maximum boost current 15 A 30 A
Voltage adjustment range *5 21.6 to 28 V (with V.ADJ)
Ripple & Noise
voltage *6
100 to 240 VAC
input *1
100 mVp-p max.
at 20 MHz of bandwidth
130 mVp-p max.
at 20 MHz of bandwidth
Input variation influence *7 0.5% max.
Load variation influence *8 1.5% max.
Temperature
variation
influence
115 to 230 VAC
input
0.05%/°C max.
Start up time
*4
115 VAC input *1 1000 ms max. 1000 ms max.
230 VAC input *1 1000 ms max. 1000 ms max.
Hold time *6 115 VAC input *1 35 ms typ. 30 ms typ.
230 VAC input *1 35 ms typ. 30 ms typ.
Additional
functions
Overload protection Yes, automatic reset
Overvoltage protection *9 Yes, 130% or higher of rated output voltage, power shut off (shut
off the input voltage and turn on the input again)
Series operation Yes (For up to two Power Supplies, external diodes are required.)
Parallel operation Yes (For up to two Power Supplies), Refer to Parallel Operation on
catalog for details.
Output indicator Yes (LED: Green)
Low-voltage detection output Yes (Photoswitch output: 30 VDC max., 50 mA max.)
Insulation Withstand voltage 3.0 kVAC for 1 min. (between all input terminals and output
terminals), current cutoff 20 mA
2.0 kVAC for 1 min. (between all input terminals and PE terminals),
current cutoff 20 mA
1.0 kVAC for 1 min. (between all output terminals and PE terminals),
current cutoff 20 mA
500 VAC for 1 min (between all output terminals and all low-voltage
detection output terminals), current cutoff 10 mA
Insulation resistance 100 MΩ min. (between all output terminals/all low-voltage
detection output terminals and all input terminals/PE terminals) at
500 VDC
Environ-
ment
Ambient operating temperature
*10
-40 to 70°C (Derating is required according to the temperature.
Refer to Engineering Data) (with no condensation or icing)
Storage temperature -40 to 85°C (with no condensation or icing)
Ambient operating humidity 95% RH max. (Storage humidity: 95% RH max.)
Vibration resistance 10 to 55 Hz, maximum 5G, 0.42 mm half amplitude for 2 h each in
X, Y, and Z directions
Shock resistance 150 m/s2, 3 times each in ±X, ±Y, ±Z directions
Reliability MTBF 135,000 hrs min. (Refer to Data Sheet Reference Value)
Life expectancy *11 10 years min.
Con-
struction
Weight 700 g max. 1150 g max.
Cooling fan No
Degree of protection IP20 by EN/IEC 60529
Standards Harmonic current emissions Conforms to EN 61000-3-2
EMI Conducted
Emissions
Conforms to EN 61204-3 Class B, EN 55011 Class B
Radiated
Emissions
Conforms to EN 61204-3 Class B, EN 55011 Class B
EMS Conforms to EN 61204-3 high severity levels
Safety standards UL Listing: UL 508
cUL: CSA C22.2 No107.1
UL UR: UL 62368-1 (Recognition) OVCII (≤ 3000 m) Pol2
cUR: CSA C22.2 No.62368-1 OVCII (≤ 3000 m) Pol2
EN: EN 62477-1 OVCIII (≤ 2000 m) OVCII (2000 m≤ and≤3000) Pol2,
EN 62368-1 OVCII (≤ 3000 m) Pol2
PELV (EN/IEC 60204-1) *12
EN/IEC 61558-2-16:2009+A1:2013 *12
BIS: IS 13252 (Part1) *12
Marine Standards *12 Lloyd's register
SEMI Conforms to F47-0706 (200 to 240 VAC input)
Power ratings Rated input voltage Rated output voltage (DC) Rated output current Maximum boost current Model number
30 W 100 to 240 (VAC allowable range: 85 to 264 VAC or 90 to 350 VDC) 24 V 1.3 A 1.56 A S8VK-S03024
60 W 24 V 2.5 A 3 A S8VK-S06024
120 W 24 V 5 A 6 A S8VK-S12024
240 W 24 V 10 A 15 A S8VK-S24024
480 W 24 V 20 A 30 A S8VK-S48024
Catalog Name
Catalog Number[size]
Last Update
S8VK-S Data Sheet T205-E1-14
[5868KB]
Jul 08, 2024
S8VK-W/S8VK-S Catalog T235-E1-05
[2061KB]
Nov 18, 2024
S8VK-S/S8FS-G Power Supply Guide Catalog T209-E1-09
[2280KB]
Oct 23, 2023
XW6T Catalog G139-E1-06
[4370KB]
Nov 13, 2023
Value Design for Panel Catalog Y235-E1-07
[5229KB]
May 19, 2025

Applications

  • Compact control panels
  • Sensor and controller power supply
  • Building automation
  • Packaging machines
  • Small machinery and conveyors

Why Choose

  • Slim body = More space in control cabinets
  • Global input voltage compatibility
  • Simple DIN rail installation
  • Excellent cost-performance ratio
  • Robust, fanless design for reliability

Inquiry Now

Brands

Global Brands We Represent in Automation & Switchgear

Scan the QR to call