Founded in 2012, Shree Vijayvargiya Technologies Pvt. Ltd. is a leading provider of industrial and commercial supplies, specializing in industrial switchgear and automation products. We focus on excellence, innovation, and customer delight across wholesale, distribution, and automation solutions.

Our Socials

Omron S8FS-G SMPS Indicator

Omron S8FS-G Series SMPS Indicator

The Omron S8FS-G series offers robust, long-lasting power supply solutions for demanding industrial environments. Engineered with enhanced durability, wide operating temperatures, and premium components, the S8FS-G series is ideal for control panels, factory automation, and harsh condition applications.

Categories:

Panel Components

Key Features

  • Wide Input Voltage Range:
    • Supports 85 to 264 VAC and 90 to 350 VDC
  • High Output Reliability:
    • Delivers consistent DC output from 15W to 350W
    • Output voltage options: 5V, 12V, 15V, 24V, 48V
  • Superior Internal Components:
    • Uses Japanese electrolytic capacitors for long service life
    • Designed for 10-year operation (at 40°C, 100% load)
  • Overload, Overvoltage, and Short-Circuit Protection:
    • Increases safety and reliability
  • Harsh Environment Compatible:
    • Wide operating temperature range: -25°C to +70°C
    • Conforms to SEMI F47, suitable for semiconductor equipment
  • LED Status Indicator:
    • Power status easily visible through front LED
  • Mounting Options:
    • Chassis or DIN Rail mounting supported
  • Global Standards:
    • CE, UL, TUV approved for worldwide acceptance
Power rating 15 W
Output voltage (VDC) 5 V 12 V 15 V 24 V
Efficiency *1 100 VAC input 80% typ. 84% typ. 84% typ. 85% typ.
200 VAC input 80% typ. 84% typ. 84% typ. 86% typ.
230 VAC input 80% typ. 84% typ. 84% typ. 86% typ.
Input Voltage range *1 Single phase, 85 to 264 VAC, 80 to 370 VDC
Frequency *1 50/60 Hz (47 to 450 Hz)
Current *1 100 VAC input 0.32 A typ.
200 VAC input 0.2 A typ.
Power factor *1 ---
Leakage
current *1
100 VAC input 0.5 mA max.
200 VAC input 1 mA max.
Inrush
current *1 (for
a cold start at
25°C)
100 VAC input 14 A typ.
200 VAC input 28 A typ.
Output Rated Output Current 3 A 1.3 A 1 A 0.65 A
Voltage adjustment range *1 -10% to 15% (with V.ADJ)
Ripple & Noise
voltage *1
100 to 240
VAC input
40 mVp-p max. 40 mVp-p max. 40 mVp-p max. 60 mVp-p max.
Input variation influence *1 0.5% max.
Load variation influence *1 1.0% max.
Temperature
variation
influence
100 to 240
VAC input
0.05%/°C max.
Startup time *1 100 VAC input 1,000 ms max.
200 VAC input 1,000 ms max.
Hold time *1 100 VAC input 15 ms typ. 14 ms typ. 15 ms typ. 15 ms typ.
200 VAC input 75 ms typ. 70 ms typ. 75 ms typ. 70 ms typ.
Additional
functions
Overload protection Yes, automatic reset
Overvoltage protection *1 Yes, 120% or higher of rated output voltage, power shut off (shut off the
input voltage and turn on the input again)
Overheat protection No
Series operation Yes (For up to two Power Supplies, external diodes are required.)
Parallel operation No (However, backup operation is possible, external diodes are required.)
Remote sensing No
Remote control No
Output indicator Yes (LED: Green)
Insulation Withstand voltage 3 kVAC for 1 min. (between all input terminals and output terminals)
current cutoff 20 mA
2 kVAC for 1 min. (between all input terminals and PE terminals) current
cutoff 20 mA
1 kVAC for 1 min. (between all output terminals and PE terminals)
current cutoff 20 mA
Insulation resistance 100 MΩ min. (between all output terminals and all input terminals/PE
terminals) at 500 VDC
Environ-
ment
Ambient operating
temperature
-20 to 70°C (Derating is required according to the temperature.)
(with no condensation or icing)
Storage temperature -25 to 75°C (with no condensation or icing)
Ambient operating humidity 90% max. (Storage humidity: 90% max.)
Vibration resistance 10 to 55 Hz, 4.5 G max., 0.375-mm half amplitude for 2 h each in X, Y,
and Z directions
Shock resistance 150 m/s2, 3 times each in ±X, ±Y, ±Z directions
Reliability MTBF 135,000 hrs min.
Life expectancy *1 10 years min.
Con-
struction
Dimensions (W×H×D) Refer to Dimensions.
Weight 250 g
Cooling fan No
Degree of protection ---
Standards Harmonic current emissions Conforms to EN 61000-3-2
EMI *1 Conducted
Emissions
Conforms to EN 61204-3 Class B, EN 55011 Class B
Radiated
Emissions
Conforms to EN 61204-3 Class B, EN 55011 Class B
EMS Conforms to EN 61204-3 high severity levels
Safety Standards *2 UL 508 (Listing, excluding models with connector option)
UL 62368-1 (Recognition, OVCII [≤ 3,000 m], Pol2)
CSA C22.2 No.107.1 (excluding models with connector option)
CSA C22.2 No.62368-1 (excluding models with connector option)
EN 62477-1 (OVCIII [≤ 2,000 m], OVCII [> 2,000 m and ≤ 3,000 m], Pol2)
EN/IEC 62368-1 (OVCII [≤ 3,000 m], Pol2)
Conforms to EN/IEC 61558-2-16
Conforms to PELV (EN/IEC 60204-1)
RCM (EN61000-6-4)
Marine Standards No
SEMI Conforms to F47-0706 (200 VAC input)
Specifications Details
Efficiency The value is when both rated output voltage and rated output current are
satisfied.
Input Voltage range Do not use an inverter output for the Power Supply. Inverters with an
output frequency of 50/60 Hz are available, but the rise in the internal
temperature of the Power Supply may result in ignition or burning.
Frequency
Current The value is when both rated output voltage and rated output current are
satisfied.
Power factor The value is when both rated output voltage and rated output current are
satisfied.
Leakage current The values are determined according to the Act on Power Supply Safety of
Electrical Appliances and Materials.
Inrush current
(for a cold start at 25°C)
For a cold start at 25°C. Refer to the following figure.
Output Voltage adjustment range If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by
more than +15% of the voltage adjustment range. When adjusting the output
voltage, confirm the actual output voltage from the Power Supply and be
sure that the load is not damaged.
Ripple & Noise voltage The value is when both rated output voltage and rated output current are
satisfied.
A characteristic when the ambient operating temperature is 25°C.
Input variation influence This is the maximum variation in the output voltage when the input voltage
is gradually changed within the allowable input voltage range at the rated
output voltage and rated output current.
Load variation influence This is the value when the output current is changed from 0 A to the rated
output current while the input voltage is within the allowable input voltage.
Startup time The value is when both rated output voltage and rated output current are
satisfied.
For a cold start at 25°C. Refer to the following figure.
Hold time The value is when both rated output voltage and rated output current are
satisfied.
At 25°C. Refer to the following figure.
Additional
functions
Overvoltage protection Refer to Overvoltage Protection on Data Sheet for the time when input
voltage shuts off and input turns on again.
Reliability Life expectancy Refer to Recommended Replacement Periods and Periodic Replacement for
Preventive Maintenance on Data Sheet for details.
Standards EMI Conducted Emissions The 150-W and higher models conform to Class B when an aluminum plate
is set under the Power Supply.
Radiated Emissions
Power ratings Input voltage Output voltage (VDC) Output current Built-in fan Model
15 W 100 to 240 VAC
(Permissible range
85 to 264 VAC,
80 to 370 VDC)
*4
5 V 3 A None S8FS-G01505CD
12 V 1.3 A S8FS-G01512CD
15 V 1 A S8FS-G01515CD
24 V 0.65 A S8FS-G01524CD
30 W 5 V 6 A S8FS-G03005CD
12 V 3 A S8FS-G03012CD
15 V 2.4 A S8FS-G03015CD
24 V 1.5 A S8FS-G03024CD
50 W 5 V 8 A *1 S8FS-G05005CD
12 V 4.3 A S8FS-G05012CD
15 V 3.5 A S8FS-G05015CD
24 V 2.2 A S8FS-G05024CD
100 W 5 V 16 A *2 S8FS-G10005CD
12 V 8.5 A S8FS-G10012CD
15 V 7 A S8FS-G10015CD
24 V 4.5 A S8FS-G10024CD
S8FS-G10024CD-500 *5
150 W 5 V 21 A *3 S8FS-G15005CD
12 V 13 A S8FS-G15012CD
15 V 10 A S8FS-G15015CD
24 V 6.5 A S8FS-G15024CD
S8FS-G15024CD-500 *5
48 V 3.3 A S8FS-G15048CD
300 W 100 to 240 VAC
(Permissible range
85 to 264 VAC,
120 to 370 VDC)
12 V 25 A Yes S8FS-G30012CD
15 V 20 A S8FS-G30015CD
24 V 14 A S8FS-G30024CD
S8FS-G30024CD-500 *6
48 V 7 A S8FS-G30048CD
600 W 100 to 240 VAC
(Permissible range
85 to 264 VAC,
120 to 350 VDC)
12 V 50 A S8FS-G60012CD
15 V 40 A S8FS-G60015CD
24 V 27 A S8FS-G60024CD
S8FS-G60024CD-500 *6
48 V 13 A S8FS-G60048CD
Catalog Name
Catalog Number[size]
Last Update
S8FS-G Data Sheet T207-E1-14
[7846KB]
Jun 17, 2024
S8FS-G Catalog T208-E1-03
[758KB]
Aug 01, 2022
S8VK-S/S8FS-G Power Supply Guide Catalog T209-E1-09
[2280KB]
Oct 23, 2023
S8JX-N/S8JX-G Series Replacement Brackets T216-E1-01
[4869KB]
Aug 01, 2019
S8JX-P Series Replacement Brackets T217-E1-02
[4550KB]
Oct 23, 2023
S8VM Series Replacement Brackets T218-E1-01
[6699KB]
Aug 01, 2019

Applications

  • PLCs, sensors, relays, and HMI power
  • Factory automation systems
  • Control and instrumentation panels
  • Semiconductor & packaging machines
  • Electrical panels in extreme environments

Why Choose

  • Designed for longevity in high-load, high-temperature environments
  • Offers a robust alternative to general-purpose SMPS units
  • Suitable for mission-critical equipment where downtime is costly
  • Value-for-money with Omron reliability

Inquiry Now

Brands

Global Brands We Represent in Automation & Switchgear

Scan the QR to call