Omron S8FS-G Series SMPS Indicator
The Omron S8FS-G series offers robust, long-lasting power supply solutions for demanding industrial environments. Engineered with enhanced durability, wide operating temperatures, and premium components, the S8FS-G series is ideal for control panels, factory automation, and harsh condition applications.
Categories:
Panel ComponentsKey Features
-
Wide Input Voltage Range:
- Supports 85 to 264 VAC and 90 to 350 VDC
-
High Output Reliability:
- Delivers consistent DC output from 15W to 350W
- Output voltage options: 5V, 12V, 15V, 24V, 48V
-
Superior Internal Components:
- Uses Japanese electrolytic capacitors for long service life
- Designed for 10-year operation (at 40°C, 100% load)
-
Overload, Overvoltage, and Short-Circuit Protection:
- Increases safety and reliability
-
Harsh Environment Compatible:
- Wide operating temperature range: -25°C to +70°C
- Conforms to SEMI F47, suitable for semiconductor equipment
-
LED Status Indicator:
- Power status easily visible through front LED
-
Mounting Options:
- Chassis or DIN Rail mounting supported
-
Global Standards:
- CE, UL, TUV approved for worldwide acceptance
| Power rating | 15 W | |||||
|---|---|---|---|---|---|---|
| Output voltage (VDC) | 5 V | 12 V | 15 V | 24 V | ||
| Efficiency *1 | 100 VAC input | 80% typ. | 84% typ. | 84% typ. | 85% typ. | |
| 200 VAC input | 80% typ. | 84% typ. | 84% typ. | 86% typ. | ||
| 230 VAC input | 80% typ. | 84% typ. | 84% typ. | 86% typ. | ||
| Input | Voltage range *1 | Single phase, 85 to 264 VAC, 80 to 370 VDC | ||||
| Frequency *1 | 50/60 Hz (47 to 450 Hz) | |||||
| Current *1 | 100 VAC input | 0.32 A typ. | ||||
| 200 VAC input | 0.2 A typ. | |||||
| Power factor *1 | --- | |||||
| Leakage
current *1 |
100 VAC input | 0.5 mA max. | ||||
| 200 VAC input | 1 mA max. | |||||
| Inrush
current *1 (for a cold start at 25°C) |
100 VAC input | 14 A typ. | ||||
| 200 VAC input | 28 A typ. | |||||
| Output | Rated Output Current | 3 A | 1.3 A | 1 A | 0.65 A | |
| Voltage adjustment range *1 | -10% to 15% (with V.ADJ) | |||||
| Ripple & Noise
voltage *1 |
100 to 240
VAC input |
40 mVp-p max. | 40 mVp-p max. | 40 mVp-p max. | 60 mVp-p max. | |
| Input variation influence *1 | 0.5% max. | |||||
| Load variation influence *1 | 1.0% max. | |||||
| Temperature
variation influence |
100 to 240
VAC input |
0.05%/°C max. | ||||
| Startup time *1 | 100 VAC input | 1,000 ms max. | ||||
| 200 VAC input | 1,000 ms max. | |||||
| Hold time *1 | 100 VAC input | 15 ms typ. | 14 ms typ. | 15 ms typ. | 15 ms typ. | |
| 200 VAC input | 75 ms typ. | 70 ms typ. | 75 ms typ. | 70 ms typ. | ||
| Additional
functions |
Overload protection | Yes, automatic reset | ||||
| Overvoltage protection *1 | Yes, 120% or higher of rated output voltage, power shut off (shut off the
input voltage and turn on the input again) |
|||||
| Overheat protection | No | |||||
| Series operation | Yes (For up to two Power Supplies, external diodes are required.) | |||||
| Parallel operation | No (However, backup operation is possible, external diodes are required.) | |||||
| Remote sensing | No | |||||
| Remote control | No | |||||
| Output indicator | Yes (LED: Green) | |||||
| Insulation | Withstand voltage | 3 kVAC for 1 min. (between all input terminals and output terminals)
current cutoff 20 mA |
||||
| 2 kVAC for 1 min. (between all input terminals and PE terminals) current
cutoff 20 mA |
||||||
| 1 kVAC for 1 min. (between all output terminals and PE terminals)
current cutoff 20 mA |
||||||
| Insulation resistance | 100 MΩ min. (between all output terminals and all input terminals/PE
terminals) at 500 VDC |
|||||
| Environ-
ment |
Ambient operating
temperature |
-20 to 70°C (Derating is required according to the temperature.)
(with no condensation or icing) |
||||
| Storage temperature | -25 to 75°C (with no condensation or icing) | |||||
| Ambient operating humidity | 90% max. (Storage humidity: 90% max.) | |||||
| Vibration resistance | 10 to 55 Hz, 4.5 G max., 0.375-mm half amplitude for 2 h each in X, Y,
and Z directions |
|||||
| Shock resistance | 150 m/s2, 3 times each in ±X, ±Y, ±Z directions | |||||
| Reliability | MTBF | 135,000 hrs min. | ||||
| Life expectancy *1 | 10 years min. | |||||
| Con-
struction |
Dimensions (W×H×D) | Refer to Dimensions. | ||||
| Weight | 250 g | |||||
| Cooling fan | No | |||||
| Degree of protection | --- | |||||
| Standards | Harmonic current emissions | Conforms to EN 61000-3-2 | ||||
| EMI *1 | Conducted
Emissions |
Conforms to EN 61204-3 Class B, EN 55011 Class B | ||||
| Radiated
Emissions |
Conforms to EN 61204-3 Class B, EN 55011 Class B | |||||
| EMS | Conforms to EN 61204-3 high severity levels | |||||
| Safety Standards *2 | UL 508 (Listing, excluding models with connector option)
UL 62368-1 (Recognition, OVCII [≤ 3,000 m], Pol2) CSA C22.2 No.107.1 (excluding models with connector option) CSA C22.2 No.62368-1 (excluding models with connector option) EN 62477-1 (OVCIII [≤ 2,000 m], OVCII [> 2,000 m and ≤ 3,000 m], Pol2) EN/IEC 62368-1 (OVCII [≤ 3,000 m], Pol2) Conforms to EN/IEC 61558-2-16 Conforms to PELV (EN/IEC 60204-1) RCM (EN61000-6-4) |
|||||
| Marine Standards | No | |||||
| SEMI | Conforms to F47-0706 (200 VAC input) | |||||
| Specifications | Details | ||
|---|---|---|---|
| Efficiency | The value is when both rated output voltage and rated output current are
satisfied. |
||
| Input | Voltage range | Do not use an inverter output for the Power Supply. Inverters with an
output frequency of 50/60 Hz are available, but the rise in the internal temperature of the Power Supply may result in ignition or burning. |
|
| Frequency | |||
| Current | The value is when both rated output voltage and rated output current are
satisfied. |
||
| Power factor | The value is when both rated output voltage and rated output current are
satisfied. |
||
| Leakage current | The values are determined according to the Act on Power Supply Safety of
Electrical Appliances and Materials. |
||
| Inrush current
(for a cold start at 25°C) |
For a cold start at 25°C. Refer to the following figure. | ||
| Output | Voltage adjustment range | If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by
more than +15% of the voltage adjustment range. When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that the load is not damaged. |
|
| Ripple & Noise voltage | The value is when both rated output voltage and rated output current are
satisfied. A characteristic when the ambient operating temperature is 25°C. |
||
| Input variation influence | This is the maximum variation in the output voltage when the input voltage
is gradually changed within the allowable input voltage range at the rated output voltage and rated output current. |
||
| Load variation influence | This is the value when the output current is changed from 0 A to the rated
output current while the input voltage is within the allowable input voltage. |
||
| Startup time | The value is when both rated output voltage and rated output current are
satisfied. For a cold start at 25°C. Refer to the following figure. |
||
| Hold time | The value is when both rated output voltage and rated output current are
satisfied. At 25°C. Refer to the following figure. |
||
| Additional
functions |
Overvoltage protection | Refer to Overvoltage Protection on Data Sheet for the time when input
voltage shuts off and input turns on again. |
|
| Reliability | Life expectancy | Refer to Recommended Replacement Periods and Periodic Replacement for
Preventive Maintenance on Data Sheet for details. |
|
| Standards | EMI | Conducted Emissions | The 150-W and higher models conform to Class B when an aluminum plate
is set under the Power Supply. |
| Radiated Emissions | |||
| Power ratings | Input voltage | Output voltage (VDC) | Output current | Built-in fan | Model |
|---|---|---|---|---|---|
| 15 W | 100 to 240 VAC
(Permissible range 85 to 264 VAC, 80 to 370 VDC) *4 |
5 V | 3 A | None | S8FS-G01505CD |
| 12 V | 1.3 A | S8FS-G01512CD | |||
| 15 V | 1 A | S8FS-G01515CD | |||
| 24 V | 0.65 A | S8FS-G01524CD | |||
| 30 W | 5 V | 6 A | S8FS-G03005CD | ||
| 12 V | 3 A | S8FS-G03012CD | |||
| 15 V | 2.4 A | S8FS-G03015CD | |||
| 24 V | 1.5 A | S8FS-G03024CD | |||
| 50 W | 5 V | 8 A *1 | S8FS-G05005CD | ||
| 12 V | 4.3 A | S8FS-G05012CD | |||
| 15 V | 3.5 A | S8FS-G05015CD | |||
| 24 V | 2.2 A | S8FS-G05024CD | |||
| 100 W | 5 V | 16 A *2 | S8FS-G10005CD | ||
| 12 V | 8.5 A | S8FS-G10012CD | |||
| 15 V | 7 A | S8FS-G10015CD | |||
| 24 V | 4.5 A | S8FS-G10024CD | |||
| S8FS-G10024CD-500 *5 | |||||
| 150 W | 5 V | 21 A *3 | S8FS-G15005CD | ||
| 12 V | 13 A | S8FS-G15012CD | |||
| 15 V | 10 A | S8FS-G15015CD | |||
| 24 V | 6.5 A | S8FS-G15024CD | |||
| S8FS-G15024CD-500 *5 | |||||
| 48 V | 3.3 A | S8FS-G15048CD | |||
| 300 W | 100 to 240 VAC
(Permissible range 85 to 264 VAC, 120 to 370 VDC) |
12 V | 25 A | Yes | S8FS-G30012CD |
| 15 V | 20 A | S8FS-G30015CD | |||
| 24 V | 14 A | S8FS-G30024CD | |||
| S8FS-G30024CD-500 *6 | |||||
| 48 V | 7 A | S8FS-G30048CD | |||
| 600 W | 100 to 240 VAC
(Permissible range 85 to 264 VAC, 120 to 350 VDC) |
12 V | 50 A | S8FS-G60012CD | |
| 15 V | 40 A | S8FS-G60015CD | |||
| 24 V | 27 A | S8FS-G60024CD | |||
| S8FS-G60024CD-500 *6 | |||||
| 48 V | 13 A | S8FS-G60048CD |
|
Catalog Name
|
Catalog Number[size]
|
Last Update
|
|---|---|---|
| S8FS-G Data Sheet | T207-E1-14 [7846KB] |
Jun 17, 2024 |
| S8FS-G Catalog | T208-E1-03 [758KB] |
Aug 01, 2022 |
| S8VK-S/S8FS-G Power Supply Guide Catalog | T209-E1-09 [2280KB] |
Oct 23, 2023 |
| S8JX-N/S8JX-G Series Replacement Brackets | T216-E1-01 [4869KB] |
Aug 01, 2019 |
| S8JX-P Series Replacement Brackets | T217-E1-02 [4550KB] |
Oct 23, 2023 |
| S8VM Series Replacement Brackets | T218-E1-01 [6699KB] |
Aug 01, 2019 |
Applications
- PLCs, sensors, relays, and HMI power
- Factory automation systems
- Control and instrumentation panels
- Semiconductor & packaging machines
- Electrical panels in extreme environments
Why Choose
- Designed for longevity in high-load, high-temperature environments
- Offers a robust alternative to general-purpose SMPS units
- Suitable for mission-critical equipment where downtime is costly
- Value-for-money with Omron reliability
Inquiry Now
Brands