Omron MY-GS Series Relay Panel Components
The Omron MY-GS Series relays are next-generation general-purpose plug-in relays designed to support smarter, safer, and more compact control panels. As an upgrade to the widely adopted MY series, MY-GS relays deliver improved visibility, maintainability, and panel space savings, while offering high electrical durability and switching reliability.
Categories:
Panel ComponentsKey Features
- Transparent Housing with LED Indicator – Clear operational status visibility with mechanical flag and built-in LED (AC/DC types)
- Test Button & Mechanical Operation Indicator – Manual operation check with lockable test button and red flag indicator
- Standardized Compact Design – Conforms to IEC standards with standard 35mm DIN-rail mounting via sockets
- Wide Coil Voltage Range – Available in DC 6V to 110V and AC 6V to 240V, covering diverse control needs
- High Switching Capacity – Handles up to 10A at 250VAC / 30VDC, ideal for resistive and inductive loads
- Secure & Reliable Socket Mounting – Compatible with PYF-Z series sockets, with push-in plus terminal blocks for tool-free wiring
| Item | Rated current (mA) |
Coil resistance (Ω) |
Coil inductance (H) |
Must- operate voltage |
Must- release voltage |
Maximum voltage |
Power consumption (VA, W) |
|||
|---|---|---|---|---|---|---|---|---|---|---|
| Rated voltage | 50 Hz | 60 Hz | Armature OFF |
Armature ON |
Percentage of rated voltage | |||||
| AC | 12 | 106.5 | 91 | 46 | 0.17 | 0.33 | 80% max. *1 |
30% min. *2 |
110% | Approx. 0.9 to 1.3 (at 60 Hz) |
| 24 | 53.8 | 46 | 180 | 0.69 | 1.3 | |||||
| 48 | 25.7 | 21.1 | 788 | 3.22 | 5.66 | |||||
| 100/110 | 11.7/12.9 | 10.0/11.0 | 3,750 | 14.54 | 24.6 | |||||
| 110/120 | 9.9/10.8 | 8.4/9.2 | 4,430 | 19.2 | 32.1 | |||||
| 200/220 | 6.2/6.8 | 5.3/5.8 | 12,950 | 54.75 | 94.07 | |||||
| 220/240 | 5.2/6.2 | 4.3/5.0 | 15,920 | 83.5 | 136.4 | |||||
| DC | 6 | 146 (151) | 41.0 (39.8) | 0.17 | 0.33 | 10% min. *2 |
Approx. 0.9 | |||
| 12 | 72.7 (75) | 165 (160) | 0.73 | 1.37 | ||||||
| 24 | 36.3 (37.7) | 662 (636) | 3.2 | 5.72 | ||||||
| 48 | 17.6 (18.8) | 2,725 (2,560) | 10.6 | 21.0 | ||||||
| 100/110 | 8.7 (9.0)/9.6 (9.9) | 11,440 (11,100) | 45.6 | 86.2 | ||||||
| 220 | 3.6 | 60,394 | 362.3 | 452.9 | Approx. 0.8 | |||||
| Model | Connection | Number of Pins | Terminal Type | Ambient Operating Temperature | Ambient Humidity | Continuous Carry Current | Dielectric Strength | Insulation Resistance *1 | Weight | ||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Between contact terminals of same polarity | Between contact terminals of different polarity | Between coil and contact terminals | |||||||||
| PYFZ-08-E | Front | 8 | Screw terminal | -55 to 70°C | 5% to 85% RH | 10 A | 2,250 VAC 1 min | 2,250 VAC 1 min | 2,250 VAC 1 min | 1,000 MΩ min. (500 VDC) | Approx. 32 g |
| PYF08A-N | -55 to 55°C | 5% to 85% RH | 7 A *3 | 2,000 VAC 1 min | 2,000 VAC 1 min | 2,000 VAC 1 min | 1,000 MΩ min. (500 VDC) | Approx. 32 g | |||
| PYF-08-PU | Push-In Plus Terminal | -40 to 70°C | 5% to 85% RH | 10 A *2 | 2,000 VAC 1 min | 2,000 VAC 1 min | 2,000 VAC 1 min | 1,000 MΩ min. (500 VDC) | Approx. 80 g | ||
| PYFZ-14-E | 14 | Screw terminal | -55 to 70°C | 5% to 85% RH | 6 A | 2,250 VAC 1 min | 2,250 VAC 1 min | 2,250 VAC 1 min | 1,000 MΩ min. (500 VDC) | Approx. 50 g | |
| PYF14A-N | -55 to 55°C | 5% to 85% RH | 5 A *3 | 2,000 VAC 1 min | 2,000 VAC 1 min | 2,000 VAC 1 min | 1,000 MΩ min. (500 VDC) | Approx. 50 g | |||
| PYF-14-PU | Push-In Plus Terminal | -40 to 70°C | 5% to 85% RH | 6 A | 2,000 VAC 1 min | 2,000 VAC 1 min | 2,000 VAC 1 min | 1,000 MΩ min. (500 VDC) | Approx. 87 g | ||
| PY08-02 | Back | 8 | PCB terminals | -55 to 70°C | 5% to 85% RH | 7 A | 1,500 VAC 1 min | 1,500 VAC 1 min | 1,500 VAC 1 min | 100 MΩ min. | Approx. 7.2 g |
| PY14-02 | 14 | -55 to 70°C | 5% to 85% RH | 3 A | 1,500 VAC 1 min | 1,500 VAC 1 min | 1,500 VAC 1 min | 100 MΩ min. | Approx. 10 g | ||
Standard model without operation indicator
| Number of poles | Model | Rated voltage (V) |
|---|---|---|
| 2 | MY2-GS-R | 12, 24, 48, 100/110, 110/120, 200/220, 220/240 VAC
6, 12, 24, 48, 100/110 VDC |
| 4 | MY4-GS-R | 12, 24, 48, 100/110, 110/120, 200/220, 220/240 VAC
6, 12, 24, 48, 100/110 VDC |
Standard model with operation indicator
| Number of poles | Model | Rated voltage (V) |
|---|---|---|
| 2 | MY2N-GS-R | 12, 24, 48, 100/110, 110/120, 200/220, 220/240 VAC
6, 12, 24, 48, 100/110, 220 VDC |
| 4 | MY4N-GS-R | 12, 24, 48, 100/110, 110/120, 200/220, 220/240 VAC
6, 12, 24, 48, 100/110, 220 VDC |
Standard model with operation indicator and latching lever
| Number of poles | Model | Rated voltage (V) |
|---|---|---|
| 2 | MY2IN-GS-R | 12, 24, 48, 100/110, 110/120, 200/220, 220/240 VAC
6, 12, 24, 48, 100/110, 220 VDC |
| 4 | MY4IN-GS-R | 12, 24, 48, 100/110, 110/120, 200/220, 220/240 VAC
6, 12, 24, 48, 100/110, 220 VDC |
Models with built-in diodes for coil surge absorption with operation indicator (14: +)
| Number of poles | Model | Rated voltage (V) |
|---|---|---|
| 2 | MY2N-D2-GS-R | 12, 24, 48, 100/110, 220 VDC |
| 4 | MY4N-D2-GS-R | 12, 24, 48, 100/110, 220 VDC |
Models with built-in diodes for coil surge absorption with operation indicator (13: +)
| Number of poles | Model | Rated voltage (V) |
|---|---|---|
| 2 | MY2N-D1-GS-R | 12, 24, 48, 100/110 VDC |
| 4 | MY4N-D1-GS-R | 12, 24, 48, 100/110 VDC |
Models with built-in diodes for coil surge absorption with operation indicator and latching lever (14: +)
| Number of poles | Model | Rated voltage (V) |
|---|---|---|
| 2 | MY2IN-D2-GS-R | 12, 24, 48, 100/110, 220 VDC |
| 4 | MY4IN-D2-GS-R | 12, 24, 48, 100/110, 220 VDC |
Models with built-in diodes for coil surge absorption with operation indicator and latching lever (13: +)
| Number of poles | Model | Rated voltage (V) |
|---|---|---|
| 2 | MY2IN-D1-GS-R | 12, 24, 48, 100/110 VDC |
| 4 | MY4IN-D1-GS-R | 12, 24, 48, 100/110 VDC |
Models with built-in CR circuits for coil surge absorption with operation indicator
| Number of poles | Model | Rated voltage (V) |
|---|---|---|
| 2 | MY2N-CR-GS-R | 100/110, 110/120, 200/220, 220/240 VAC |
| 4 | MY4N-CR-GS-R | 100/110, 110/120, 200/220, 220/240 VAC |
Models with built-in CR circuits for coil surge absorption with operation indicator and latching lever
| Number of poles | Model | Rated voltage (V) |
|---|---|---|
| 2 | MY2IN-CR-GS-R | 100/110, 110/120, 200/220, 220/240 VAC |
| 4 | MY4IN-CR-GS-R | 100/110, 110/120, 200/220, 220/240 VAC |
|
Catalog Name
|
Catalog Number[size]
|
Last Update
|
|---|---|---|
| MY-GS Data Sheet | --- [4270KB] |
Oct 01, 2024 |
| MY-GS Catalog | J196-E1-09 [1236KB] |
Apr 21, 2025 |
Applications
- Control panels and automation panels
- Machine tools, conveyors, and packaging lines
- Lighting, motor, and solenoid control
- Building automation and HVAC systems
Why Choose
- Designed for smart control panels with reduced depth and clearer labeling
- Enhances safety and inspection efficiency with visual operation indicators
- Quick maintenance and testing via lockable test switch
- Supports push-in plus sockets for faster, tool-less wiring
Inquiry Now
Brands