Founded in 2012, Shree Vijayvargiya Technologies Pvt. Ltd. is a leading provider of industrial and commercial supplies, specializing in industrial switchgear and automation products. We focus on excellence, innovation, and customer delight across wholesale, distribution, and automation solutions.

Our Socials

Omron K8AK-PM Voltage/Current Monitoring Components

Omron K8AK-PM Series Voltage/Current Monitoring Components

The Omron K8AK-PM Series is a compact, high-reliability voltage and current monitoring relay designed to protect equipment from abnormal supply conditions. With precise detection, adjustable thresholds, and multiple output options, it’s ideal for monitoring single-phase and three-phase power systems in industrial control panels.

Categories:

Panel Components

Key Features

  • High resistance to inverter noise for stable operation
  • Monitors overvoltage, undervoltage, phase sequence, and phase loss for 3-phase 3-wire or 4-wire systems in a single unit
  • Switch-selectable for 3-phase 3-wire or 4-wire power supply
  • Two independent SPDT output relays (5 A at 250 VAC resistive) for separate overvoltage and undervoltage outputs
  • Supports global power specifications with switchable settings
  • LED indicators for clear output status monitoring
Specifications Details
Rated input
voltage
K8AK-PM1 Three-phase, three-wire Mode: 200, 220, 230 and 240 VAC
Three-phase, four-wire Mode: 115, 127, 133 and 138 VAC
K8AK-PM2 Three-phase, three-wire Mode: 380, 400, 415 and 480 VAC
Three-phase, four-wire Mode: 220, 230, 240 and 277 VAC
Input load K8AK-PM1: Approx. 4.4 VA
K8AK-PM2: Approx. 4.4 VA
Operating value setting range
(OVER, UNDER)
Overvoltage
-30% to 25% of rated input voltage
Undervoltage
-30% to 25% of rated input voltage
Note: The rated input voltage can be switched using the DIP switch.
Operating value 100% operation at set value
Reset value 5% of operating value (fixed)
Reset method Automatic reset
Operating time
setting range (T)
Overvoltage/
undervoltage
0.1 to 30 s
Phase sequence 0.1 s±0.05 s
Phase loss 0.1 s max.
Power ON lock time (LOCK) 1 s or 5 s (Switched using DIP switch.)
Indicators Power (PWR): Green, Relay output (RY): Yellow, OVER/UNDER: Red
Output relays Two SPDT relays (NC operation)
Output relay ratings Rated load
Resistive load
5 A at 250 VAC
5 A at 30 VDC
Maximum switching capacity: 1,250 VA, 150 W
Minimum load: 5 VDC, 10 mA (reference values)
Mechanical life: 10 million operations min.
Electrical life: 5 A at 250 VAC or 30 VDC: 50,000 operations
3 A at 250 VAC/30 VDC: 100,000 operations
Ambient operating temperature -20 to 60°C (with no condensation or icing)
Storage temperature -25 to 65°C (with no condensation or icing)
Ambient operating humidity 25% to 85% (with no condensation)
Storage humidity 25% to 85% (with no condensation)
Altitude 2,000 m max.
Terminal screw tightening torque 0.49 to 0.59 N·m
Terminal wiring method Recommended wire
Solid wire: 2.5 mm2
Twisted wires: AWG16, AWG18
Note: 1. Ferrules with insulating sleeves must be used with twisted wires.
2. Two wires can be twisted together.
Recommended ferrules
Al 1,5-8BK (for AWG16) manufactured by Phoenix Contacts
Al 1-8RD (for AWG18) manufactured by Phoenix Contact
Al 0,75-8GY (for AWG18) manufactured by Phoenix Contact
Case color N1.5
Case material PC and ABS, UL 94 V-0
Weight Approx. 150 g
Mounting Mounts to DIN Track.
Dimensions 22.5 × 90 × 100 mm (W×H×D)
Specifications Details
Input frequency 50/60 Hz
Overload capacity Continuous input at 115% of maximum input, 10 s at 125% (up to 600 VAC).
Repeat
accuracy
Operating value ±0.5% full scale (at 25°C and an ambient humidity of 65% at the rated power supply
voltage, DC and 50/60 Hz sine wave input)
Operating time ±50 ms (at 25°C and 65% humidity, rated power supply voltage)
Applicable
standards
Conforming standards EN 60947-5-1
Installation environment (pollution level 2, installation category III)
EMC EN 60947-5-1
Safety standards UL 508 (Recognition), Korean Radio Waves Act (Act 10564),
CSA: C22.2 No.14, CCC: GB/T 14048.5
Insulation resistance 20 MΩ
Between all external terminals and the case
Between all input terminals and all output terminals
Dielectric strength 2,000 VAC for 1 min
Between all external terminals and the case
Between all input terminals and all output terminals
Noise immunity 1,500 V power supply terminal common/normal mode
Square-wave noise of ±1 μs/100 ns pulse width with 1-ns rise time
Vibration resistance Frequency: 10 to 55 Hz, 0.35-mm single amplitude
10 sweeps of 5 min each in X,Y, and Z directions
Shock resistance 100 m/s2, 3 times each in 6 directions along 3 axes
Degree of protection Terminals: IP20
Specifications Details
Rated input* Model
3-phase 3-wire mode 200, 220, 230, 240 VAC K8AK-PM1
3-phase 4-wire mode 115, 127, 133, 138 VAC
3-phase 3-wire mode 380, 400, 415, 480 VAC K8AK-PM2
3-phase 4-wire mode 220, 230, 240, 277 VAC
Catalog Name
Catalog Number[size]
Last Update
K8AK-PM Catalog N185-E1-03
[2633KB]
Jan 04, 2024
Measuring and Monitoring Relays Application Guide N222-E1-02
[3240KB]
Oct 15, 2024

Applications

  • Industrial machinery protection
  • Motor control and pump systems
  • HVAC system supply monitoring
  • Process automation power safety
  • Renewable energy system voltage and current protection

Why Choose

  • Protects equipment from costly damage due to abnormal voltage or current
  • Compact DIN-rail design saves valuable panel space
  • Quick setup with front-panel dial adjustments
  • Multiple monitoring parameters in one device reduces component count

Inquiry Now

Brands

Global Brands We Represent in Automation & Switchgear

Scan the QR to call