Founded in 2012, Shree Vijayvargiya Technologies Pvt. Ltd. is a leading provider of industrial and commercial supplies, specializing in industrial switchgear and automation products. We focus on excellence, innovation, and customer delight across wholesale, distribution, and automation solutions.

Our Socials

Omron K3HB-V Load Cell Indicator

Omron K3HB-V Series Load Cell Indicator

The Omron K3HB-V is a versatile and fast-response digital panel indicator specifically designed for weighing and load cell applications. It offers high-speed sampling, built-in excitation voltage, and easy-to-read digital display, making it ideal for dynamic measurement and real-time process control.

Categories:

Panel Components

Key Features

  • Easy recognition of judgement results using color display that can be switched between red and green. *
  • Equipped with a position meter for monitoring operating status trends.
  • External event input allows use in various measurement and discrimination applications.
  • Input 0.001 mVDC or higher (0.000 to 19.999 mV range supported).
    External power takeoff of 100 mA at 10 VDC provided. (Models with 5-VDC power takeoff also available.)
  • Series expanded to include DeviceNet models.
  • Short body with depth of only 95 mm (from behind the front panel), or 97 mm for DeviceNet models.
  • UL certification approval (Certification Mark License).
  • CE Marking conformance by third party assessment body.
  • Water-resistant enclosure conforms to NEMA 4X (equivalent to IP66).
  • Capable of high-speed sampling at 50 times per second (20 ms).
  • Easy-to-set two-point scaling allows conversion and display of any user-set values.
Specifications Details
Power supply voltage 100 to 240 VAC (50/60 Hz), 24 VAC/VDC, DeviceNet power supply: 24 VDC
Allowable power supply voltage range 85% to 110% of the rated power supply voltage, DeviceNet power supply: 11 to 25 VDC
Power consumption *1 100 to 240 V: 18 VA max. (max. load) 24 VAC/DC: 11 VA/7 W max. (max. load)
Current consumption DeviceNet power supply: 50 mA max. (24 VDC)
Input DC voltage
A/D conversion method Delta-Sigma method
External power supply 10 VDC ±5%, 100 mA (models with external power supply only) or 5 VDC, 100 mA (models with external power supply only)
Event inputs *2 Timing input NPN open collector or no-voltage contact signal ON residual voltage: 3 V max. ON current at 0 Ω: 17 mA max. Max. applied voltage: 30 VDC max. OFF leakage current: 1.5 mA max.
Startup compensation timer input NPN open collector or no-voltage contact signal ON residual voltage: 2 V max. ON current at 0 Ω: 4 mA max. Max. applied voltage: 30 VDC max. OFF leakage current: 0.1 mA max.
Hold input
Reset input
Forced-zero input
Bank input
Output ratings (depends on the model) Relay output 250 VAC, 30 VDC, 5 A (resistive load) Mechanical life expectancy: 5,000,000 operations Electrical life expectancy: 100,000 operations
Transistor output Maximum load voltage: 24 VDC Maximum load current: 50 mA Leakage current: 100 μA max.
Linear output Linear output 0 to 20 mA DC, 4 to 20 mA DC: Load: 500 Ω max, Resolution: Approx. 10,000, Output error: ±0.5% FS Linear output 0 to 5 VDC, 1 to 5 VDC, 0 to 10 VDC: Load: 5 kΩ max, Resolution: Approx. 10,000, Output error: ±0.5% FS (1 V or less: ±0.15 V; no output for 0 V or less)
Display method Negative LCD (backlit LED) display 7-segment digital display (Character height: PV: 14.2 mm (green/red); SV: 4.9 mm (green))
Main functions Scaling function, measurement operation selection, averaging, previous average value comparison, forcedzero, zero-limit, output hysteresis, output OFF delay, output test, teaching, display value selection, display color selection, key protection, bank selection, display refresh period, maximum/minimum hold, reset
Ambient operating temperature -10 to 55°C (with no icing or condensation)
Ambient operating humidity 25% to 85%
Storage temperature -25 to 65°C (with no icing or condensation)
Altitude 2,000 m max.
Accessories Watertight packing, 2 fixtures, terminal cover, unit stickers, operation manual. DeviceNet models also include a DeviceNet connector (Hirose HR31-5.08P-5SC (01)) and crimp terminals (Hirose HR31-SC-121) *3
Specifications Details
Display range -19,999 to 99,999
Sampling period 20 ms (50 times/second)
Comparative output response time 100 ms max.
Linear output response time 150 ms max.
Insulation resistance 20 MΩ min. (at 500 VDC)
Dielectric strength 2,300 VAC for 1 min between external terminals and case
Noise immunity 100 to 240 VAC models: ±1,500 V at power supply terminals in normal or common mode (waveform with 1-ns rising edge and pulse width of 1 μs/100 ns) 24 VAC/VDC models: ±1,500 V at power supply terminals in normal or common mode (waveform with 1-ns rising edge and pulse width of 1 μs/100 ns)
Vibration resistance Frequency: 10 to 55 Hz; Acceleration: 50 m/s2, 10 sweeps of 5 min each in X, Y, and Z directions
Shock resistance 150 m/s2 (100 m/s2 for relay outputs) 3 times each in 3 axes, 6 directions
Weight Approx. 300 g (Base Unit only)
Degree of protection Front panel Conforms to NEMA 4X for indoor use (equivalent to IP66)
Rear case IP20
Terminals IP00 + finger protection (VDE0106/100)
Memory protection EEPROM (non-volatile memory) Number of rewrites: 100,000
Applicable standards UL61010-1, CSA C22.2 No. 61010-1-04 EN61010-1 (IEC61010-1): Pollution degree 2/Overvoltage category II EN61326-1
EMC EMI: EN61326-1 Industrial electromagnetic environment Electromagnetic radiation interference: CISPR 11 Group 1, Class A Terminal interference voltage: CISPR 11 Group 1, Class A EMS: EN61326-1 Industrial electromagnetic environment Electrostatic Discharge Immunity: EN61000-4-2: 4 kV (contact), 8 kV (in air) Radiated Electromagnetic Field Immunity: EN61000-4-3: 10 V/m 1 kHz sine wave amplitude modulation (80 MHz to 1 GHz, 1.4 to 2 GHz) Electrical Fast Transient/Burst Immunity: EN61000-4-4: 2 kV (power line), 1 kV (I/O signal line) Surge Immunity: EN61000-4-5: 1 kV with line (power line), 2 kV with ground (power line) Conducted Disturbance Immunity: EN61000-4-6: 3 V (0.15 to 80 MHz) Power Frequency Magnetic Immunity: EN61000-4-8: 30 A/m (50 Hz) continuous time Voltage Dips and Interruptions Immunity: EN61000-4-11: 0.5 cycle, 0°/180°, 100% (rated voltage)
Model Description
CPB Relay output (PASS: SPDT) + Sensor power supply (10 VDC ±5%, 100 mA) (See note 1.)
L1B Linear current output (0 to 20 or 4 to 20 mA DC) + Sensor power supply (10 VDC ±5%, 100 mA) (See note 2.)
L2B Linear voltage output (0 to 5, 1 to 5, or 0 to 10 VDC) + Sensor power supply (10 VDC ±5%, 100 mA) (See note 2.)
B Sensor power supply (10 VDC ±5%, 100 mA)
FLK1B Communications (RS-232C) + Sensor power supply (10 VDC ±5%, 100 mA) (See note 2.)
FLK3B Communications (RS-485) + Sensor power supply (10 VDC ±5%, 100 mA) (See note 2.)
CPE Relay output (PASS: SPDT) + Sensor power supply (5 VDC ±5%, 100 mA) (See note 1.)
L1E Linear current output (DC 0(4)–20 mA) + Sensor power supply (5 VDC ±5%, 100 mA) (See note 2.)
L2E Linear voltage output (DC 0(1)–5 V, 0–10 V) + Sensor power supply (5 VDC ±5%, 100 mA) (See note 2.)
E Sensor power supply (5 VDC ±5%, 100 mA)
FLK1E Communications (RS-232C) + Sensor power supply (5 VDC ±5%, 100 mA) (See note 2.)
FLK3E Communications (RS-485) + Sensor power supply (5 VDC ±5%, 100 mA) (See note 2.)
Catalog Name
Catalog Number[size]
Last Update
K3HB-V Data Sheet ---
[1792KB]
Jan 09, 2024

Applications

  • Industrial weighing systems
  • Batching and dosing machines
  • Packaging and filling machines
  • Material testing machines
  • Force and tension monitoring
  • Press-fit monitoring systems

Why Choose

  • Precise weighing and load monitoring in real-time
  • Supports tare, hold, peak, and zero tracking functions
  • Fast setup and intuitive operation
  • Reliable for both static and dynamic load measurement
  • Long-term stability and Omron quality assurance

Inquiry Now

Brands

Global Brands We Represent in Automation & Switchgear

Scan the QR to call