Omron H3DKZ Series Timer Panel Components
The Omron H3DKZ Series is a high-performance, slim DIN-rail mounted timer designed for precise time control in industrial automation and control panels. Known for its easy setting, long service life, and reliable performance, the H3DKZ is ideal for applications that require accurate delay, interval, or cycle timing.
Categories:
Panel ComponentsKey Features
- Wide AC/DC power supply range from 24 to 240 VAC/DC*
- ON-delay and Twin Timer models available with 12 VDC power supply*
- G-type models (H3DKZ-G) include option for 240 to 440 VAC power supply
- Compliant with EN 61812-1, CE Marked, and CCC certified
- Finger-safe terminal block for enhanced safety
| Specifications | Details | |
|---|---|---|
| Accuracy of operating time | ±1% of FS max. | |
| Setting error | ±5% of FS ±0.05 s max. * | |
| Influence of voltage | ±2% of FS max. * | |
| Influence of temperature | ±5% of FS max. * | |
| Dielectric strength |
Between current-carrying metal parts and exposed non-current-carrying metal parts: 2,000 VAC 50/60 Hz for 1 min. Between control output terminals and operating circuit: 2,000 VAC 50/60 Hz for 1 min. Between contacts not located next to each other: 1,000 VAC 50/60 Hz for 1 min. |
|
| Vibration resistance | Destruction | 0.75 mm single amplitude at 10 to 55 Hz for 2 h each in 3 directions |
| Malfunction | 0.5 mm single amplitude at 10 to 55 Hz for 10 min each in 3 directions | |
| Shock resistance | Destruction | 1,000 m/s2 — 3 times each in 6 directions |
| Malfunction | 100 m/s2 — 3 times each in 6 directions | |
| Life expectancy | Mechanical | 10 million operations min. (under no load at 1,800 operations/h) |
| Electrical | 100,000 operations min. (5 A at 250 VAC, resistive load at 360 operations/h) | |
| EMC |
(EMI) EN 61812-1 Radiated Emissions: EN 55011 Class B Emission AC Mains: EN 55011 Class B Harmonic Current: EN 61000-3-2 Voltage Fluctuations and Flicker: EN 61000-3-3 (EMS) EN 61812-1 ESD Immunity: EN 61000-4-2 — 6 kV contact, 8 kV air discharge Radiated RF Electromagnetic Field Immunity (AM Radio Waves): EN 61000-4-3 — 10 V/m (80 MHz to 1 GHz) Burst Immunity: EN 61000-4-4 — 2 kV power line, 1 kV I/O signal line Surge Immunity: EN 61000-4-5 — 2 kV common mode, 1 kV differential mode |
|
| Degree of protection | IP30 (Terminal block: IP20) | |
| Weight | Approx. 110 g | |
| H3DKZ-G | H3DKZ-GE | ||
|---|---|---|---|
| Accuracy of operating time | ±1% of FS max. | ||
| Setting error | ±5% of FS ±0.05 s max. *1 | ||
| Transfer time | Total error ± (25% of transfer time + 5 ms) max. *1 | ||
| Influence of voltage | ±2% of FS max. *1 | ||
| Influence of temperature | ±5% of FS max. *1 | ||
| Dielectric strength |
Between current-carrying metal parts and exposed non-current-carrying metal parts: 2,000 VAC 50/60 Hz for 1 min. *2 Between control output terminals and operating circuit: 2,000 VAC 50/60 Hz for 1 min. *2 Between contacts of different polarity: 2,000 VAC 50/60 Hz for 1 min. *2 Between contacts not located next to each other: 1,000 VAC 50/60 Hz for 1 min. |
||
| Vibration resistance | Destruction | 0.75 mm single amplitude at 10 to 55 Hz for 2 h each in 3 directions | |
| Malfunction | 0.5 mm single amplitude at 10 to 55 Hz for 10 min each in 3 directions | ||
| Shock resistance | Destruction | 1,000 m/s2 — 3 times each in 6 directions | |
| Malfunction | 100 m/s2 — 3 times each in 6 directions | ||
| Life expectancy | Mechanical | 10 million operations min. (under no load at 1,800 operations/h) | 10 million operations min. (under no load at 1,800 operations/h) |
| Electrical | 100,000 operations min. (5 A at 250 VAC, resistive load at 360 operations/h) | 100,000 operations min. (0.3 A at 440 VAC, resistive load at 1,800 operations/h) | |
| EMC |
(EMI) EN 61812-1 Radiated Emissions: EN 55011 Class B Emission AC Mains: EN 55011 Class B Harmonic Current: EN 61000-3-2 Voltage Fluctuations and Flicker: EN 61000-3-3 (EMS) EN 61812-1 ESD Immunity: EN 61000-4-2 — 6 kV contact discharge, 8 kV air discharge Radiated RF Electromagnetic Field Immunity (AM Radio Waves): EN 61000-4-3 — 10 V/m (80 MHz to 1 GHz) Burst Immunity: EN 61000-4-4 — 2 kV power line, 1 kV I/O signal line Surge Immunity: EN 61000-4-5 — 2 kV common mode, 1 kV differential mode |
||
| Degree of protection | IP30 (Terminal block: IP20) | ||
| Weight | Approx. 120 g | ||
ON-delay Timer (H3DKZ-A)
| Supply voltage | Control output | Model |
|---|---|---|
| 24 to 240 VAC/DC | SPDT (time-limit output) | H3DKZ-A1 |
| DPDT (time-limit output) | H3DKZ-A2 | |
| 12 VDC | SPDT (time-limit output) | H3DKZ-A1A |
| DPDT (time-limit output) | H3DKZ-A2A |
Accessories (Order Separately)
| Item | Specification | Model |
|---|---|---|
| Mounting Track | 50 cm (l) x 7.3 mm (t) | PFP-50N |
| 1 m (l) x 7.3 mm (t) | PFP-100N | |
| 1 m (l) x 16 mm (t) | PFP-100N2 | |
| End Plate | --- | PFP-M |
| Spacer | --- | PFP-S |
Model Structure
| Model | Operating modes | Terminal block | Output type | Mounting method | Accessories |
|---|---|---|---|---|---|
| H3DKZ-A2 | A: ON Delay | 9 terminals | Relay, DPDT | DIN Track mounting | User label |
| H3DKZ-A1 | 6 terminals | Relay, SPDT |
Twin Timer (H3DKZ-F)
| Supply voltage | Control output | Model |
|---|---|---|
| 24 to 240 VAC/DC | SPDT (time-limit output) | H3DKZ-F |
| 12 VDC | SPDT (time-limit output) | H3DKZ-FA |
Accessories
| Item | Specification | Model |
|---|---|---|
| Mounting Track | 50 cm (l) x 7.3 mm (t) | PFP-50N |
| 1 m (l) x 7.3 mm (t) | PFP-100N | |
| 1 m (l) x 16 mm (t) | PFP-100N2 | |
| End Plate | --- | PFP-M |
| Spacer | --- | PFP-S |
Model Structure
| Model | Operating modes | Terminal block | Output type | Mounting method | Accessories |
|---|---|---|---|---|---|
| H3DKZ-F | Flicker OFF start/flicker ON start | 6 terminals | Relay, SPDT | DIN Track mounting | User label |
Star-delta Timer (H3DKZ-G)
| Item | Specification | Model |
|---|---|---|
| Mounting Track | 50 cm (l) x 7.3 mm (t) | PFP-50N |
| 1 m (l) x 7.3 mm (t) | PFP-100N | |
| 1 m (l) x 16 mm (t) | PFP-100N2 | |
| End Plate | --- | PFP-M |
| Spacer | --- | PFP-S |
Model Structure
| Model | Operating modes | Terminal block | Output type | Mounting method | Accessories |
|---|---|---|---|---|---|
| H3DKZ-F | Flicker OFF start/flicker ON start | 6 terminals | Relay, SPDT | DIN Track mounting | User label |
Star-delta Timer
| Supply voltage | Control output | Model |
|---|---|---|
| 24 to 240 VAC/DC | Star circuit: SPDT, delta circuit: SPDT | H3DKZ-G |
| 240 to 440 VAC/DC | Star circuit: SPDT, delta circuit: SPDT | H3DKZ-GE |
Accessories
| Item | Specification | Model |
|---|---|---|
| Mounting Track | 50 cm (l) x 7.3 mm (t) | PFP-50N |
| 1 m (l) x 7.3 mm (t) | PFP-100N | |
| 1 m (l) x 16 mm (t) | PFP-100N2 | |
| End Plate | --- | PFP-M |
| Spacer | --- | PFP-S |
Model Structure
| Model | Terminal block | Operating/ resetting method | Output type | Mounting method | Accessories |
|---|---|---|---|---|---|
| H3DKZ-G | 9 terminals | Time-limit operation/ self-resetting | Time-limit (relay) Star circuit: SPDT Delta circuit: SPDT | DIN Track mounting | User label |
Power OFF-delay Timer (H3DKZ-H)
| Supply voltage | Control output | Model |
|---|---|---|
| 100 to 120 VAC | SPDT | H3DKZ-HCL |
| 200 to 240 VAC | SPDT | H3DKZ-HDL |
Accessories
| Item | Specification | Model |
|---|---|---|
| Mounting Track | 50 cm (l) x 7.3 mm (t) | PFP-50N |
| 1 m (l) x 7.3 mm (t) | PFP-100N | |
| 1 m (l) x 16 mm (t) | PFP-100N2 | |
| End Plate | --- | PFP-M |
| Spacer | --- | PFP-S |
Model Structure
| Model | Terminal block | Operating/ resetting method | Output type | Mounting method | Accessories |
|---|---|---|---|---|---|
| H3DKZ-H | 6 terminals | Instantaneous operation/ time-limit reset | Relay, SPDT | DIN Track mounting | User label |
|
Catalog Name
|
Catalog Number[size]
|
Last Update
|
|---|---|---|
| H3DKZ Data Sheet | L120-E1-02[3553KB] | Jul 10, 2023 |
Applications
- Conveyor start/stop sequencing
- Lighting and heating control
- Pump and motor delay control
- Industrial automation process timing
- HVAC system timing control
Why Choose
- Compact design saves valuable panel space
- Easy to wire and replace with standard DIN sockets
- Highly accurate timing for consistent control performance
- Durable construction for long-term operation in industrial settings
Inquiry Now
Brands